Before mounting and using the pump for the first time,
check and retorque all external fasteners. Follow
, or see the torque
tag on your pump. After the first day of operation,
retorque the fasteners.
Initial
Initial
Initial Configuration
Configuration
Configuration (AC
(AC
(AC with
with
with VFD)
VFD)
VFD)
Configure the VFD according to the motor nameplate
information.
Flush
Flush
Flush the
the
the Pump
Pump
Pump Before
Before
Before First
First
First Use
Use
Use
The pump was tested in water. If water could
contaminate the fluid you are pumping, flush the
pump thoroughly with a compatible solvent. See
.
Start
Start
Start and
and
and Adjust
Adjust
Adjust the
the
the Pump
Pump
Pump
1.
Be sure the pump is properly grounded. See
2.
Check fittings to be sure they are tight. Use a
compatible liquid thread sealant on male threads.
Tighten fluid inlet and fluid outlet fittings securely.
3.
Place the suction tube (if used) in fluid to be
pumped.
NOTE:
NOTE:
NOTE: If fluid inlet pressure to the pump is more
than 25% of outlet working pressure, the ball
check valves will not close fast enough, resulting
in inefficient pump operation.
NOTICE
NOTICE
NOTICE
Excessive fluid inlet pressure can reduce
diaphragm life.
4.
Place the end of the fluid hose into an appropriate
container.
5.
Close the fluid drain valve (L).
6.
Turn the air regulator knob (R) to match the
desired fluid stall pressure. Open all bleed-type
master air valves.
7.
If the fluid hose has a dispensing device, hold it
open. Be sure all fluid shutoff valves are open.
8.
Set the desired frequency on the VFD.
9.
Start the VFD.
10. If you are flushing, run the pump long enough to
thoroughly clean the pump and hoses.
Pressure
Pressure
Pressure Relief
Relief
Relief Procedure
Procedure
Procedure
Follow the Pressure Relief Procedure
whenever you see this symbol.
This equipment stays pressurized until pressure
is relieved manually. To help prevent serious
injury from pressurized fluid, such as splashing
in the eyes or on skin, follow the Pressure Relief
Procedure when you stop pumping and before you
clean, check, or service the equipment.
1.
Stop the VFD to remove power to the motor.
2.
Open the fluid drain valve (L) to relieve fluid
pressure. Have a container ready to catch the
drainage.
3.
Remove supply air to the pump:
a.
Unit
Unit
Unit without
without
without air
air
air compressor:
compressor:
compressor: Shut off the
master air valve (G).
b.
Unit
Unit
Unit with
with
with air
air
air compressor:
compressor:
compressor: Turn down center
section regulator (R) to zero to relieve air
pressure in center section.
Pump
Pump
Pump Shutdown
Shutdown
Shutdown
At the end of the work shift and before you check,
adjust, clean, or repair the system. Follow the
Pressure Relief Procedure, page 17
.
859.0634
17
Содержание Verderair VA-E80
Страница 24: ...Dimensions Dimensions Dimensions Dimensions Aluminum pump with compressor 24 859 0634 ...
Страница 25: ...Dimensions Aluminum pump without compressor 859 0634 25 ...
Страница 27: ...Dimensions Polypropylene pump with compressor 859 0634 27 ...
Страница 28: ...Dimensions Polypropylene pump without compressor 28 859 0634 ...
Страница 30: ...Dimensions Stainless steel pump with compressor 30 859 0634 ...
Страница 31: ...Dimensions Stainless steel pump without compressor 859 0634 31 ...
Страница 36: ...Notes Notes Notes Notes 36 859 0634 ...