Compressor
Compressor
Compressor Wiring
Wiring
Wiring
To avoid injury from fire, explosion, or electric
shock, all electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.
Follow these instructions to wire Verder Compressor
859.0502 (120V) or 859.0501 (240V).
See
, for additional information
on wire routing.
NOTE:
NOTE:
NOTE: Use only copper wire with an insulation rating
of 75°C or higher.
1.
Remove the cover from the compressor’s
electrical box.
2.
Install wiring system with proper connections (i.e.
conduit/fittings, power cable/cable grip) to the
compressor electrical box.
3.
Connect line power (120VAC or 240 VAC,
depending on your compressor) to L1 and L2/N.
Connect supply ground to
. Wire according
to local code. Torque terminals to 1.2 N•m
(10 in-lb).
4.
When powering the VFD on the same circuit as
the compressor, connect branch wiring to L1,
L2/N and Ground, then connect to the VFD.
5.
Reinstall the cover of the electrical box. Torque
screws to 6.8 N•m (60 in-lb).
Figure 8
L1
L2
B
A
KEY
KEY
KEY
A
A
A To power supply
B
B
B To controller
859.0510
17
Содержание VERDERAIR VA-E25
Страница 29: ...Dimensions typical only Figure 10 Pumps with Aluminum Fluid Sections with Compressor 859 0510 29 ...
Страница 31: ...Dimensions typical only Figure 11 Pumps with Polypropylene Fluid Sections without Compressor 859 0510 31 ...
Страница 32: ...Dimensions typical only Figure 12 Pumps with Polypropylene with Compressor 32 859 0510 ...
Страница 34: ...Dimensions typical only Figure 13 Pumps with Stainless Steel Fluid Sections without Compressor 34 859 0510 ...
Страница 35: ...Dimensions typical only Figure 14 Pumps with Stainless Steel Fluid Sections with Compressor 859 0510 35 ...
Страница 40: ...Notes Notes Notes Notes 40 859 0510 ...