![Verco Oblique Adapt Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/verco/oblique-adapt/oblique-adapt_assembly-and-operating-instructions-manual_1003541016.webp)
16
Error Code in the display of the handset (optional)
Display
Source
Remedying
HOT The
control
unit
monitors
the duty cycle (time-
controlled) and its max.
temperature. A value has
been exceeded.
Wait until the "HOT" goes out, then the
table is working properly again.
E00
M1 – Internal fault
Unplug! and contact the customer service
E01
M2 – Internal fault
E02
M3 – Internal fault
E12
M1 – Defect
Unplug!
Correct the external short circuit and / or
verify the cable to the drives
Take the control unit back in operation.
E13 M2
–
Defect
E14
M3 – Defect
E24
M1 – Overcurrent
Collision? -> resolve if necessary
max. Load exceeded -> remove the load
from the table.
If the problem still exists after that, please
contact customer service.
E25
M2 – Overcurrent
E26
M3 – Overcurrent
E36
M1 – Not connected
Motor not connected
Check cable / connector to the drive
Reset the table.
E37 M2
–
Not
connected
E38 M3
–
Not
connected
E48 Overcurrent
drive 1
Collision? -> resolve if necessary
max. Load exceeded -> remove the load
from the table.
E49 Overcurrent
drive 2
E55
Drive 1 – Synchronization
is lost
Motor position to different, if necessary
reduce the load on the table.
Reset the table.
E56
Drive 2 – Synchronization
is lost
E60
Collision identified
Optional ISP function.
Remove source.
E61
Drive replaced
The Connection to the drive is interrupted
or a new drive is connected.
Reset the table.