![Verco Oblique Adapt Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/verco/oblique-adapt/oblique-adapt_assembly-and-operating-instructions-manual_1003541012.webp)
12
Adjustment of the altitude display
If the indicated value does not match the actual height of the tabletop, the display
can be corrected as follows:
1. Press the S key and release the button again.
2. Press the DOWN key until the display start to flash (about 5 sec.)
3. Measure the table height and enter the measured value (depending on the
setting in centimeters or inches) with the UP or DOWN button. Confirm the
entry by pressing the S button.
To exit the menu without making a selection, you can wait about 10 seconds and
the height display will appear again.
Operation with HDU handset with display & memory (optional)
This handset is equipped with a display for displaying the current table height in
centimeters or inches, in addition, the storage of 4 "memory" positions (desk height)
is possible.
The Reset-LED indicates that a reset is required (see section - Reset). It lights until
the reset is completed.
The Info-LED indicates that the control unit has detected an error. At the same time
on the display instead of the current table height, an error code "EXX" will be
displayed. To resolve the error, see Section - Troubleshooting.
The LED's "Container, Flex, Ergotrainer and pin" are reserved for optional features
and are not used in standard systems. The key UP (2) and DOWN (2) operate in the
standard model as the buttons UP and DOWN