Installation details
All criteria given in the following sections reflect minimum clearances. However, each
installation must also be evaluated, taking into account the prevailing local conditions such
as proximity and height of walls, and proximity to public access areas. The heat pump must
be placed to provide clearances on all sides for maintenance and inspection.
1. The installation area must have good ventilation and the air inlet/outlet must not be
hindered.
2. The installation area must have good drainage and be built on a solid foundation.
3. Do not install the unit in areas accumulated with pollutions like aggressive gas (chlorine
or acidic), dust, sand and leaves etc.
4. For easier and better maintenance and troubleshooting, no obstacles around the unit
should be closer than 1000mm.(See Figure 1)
Figure 1
Air Inlet
Air Outlet
Over 1m
Over 1m
Over 1m
Over
1m
Heat Pump