7. Insert the cartridge into the air duct as figured below. The pointer must be directed upwards.
Then fix the wire with the protruding clamp and connect the socket connector to the circuit board.
Insert the wires under the
cable clamp and connect
the socket connector to the
circuit board.
The pointer must be
directed upwards.
8. Install the front part of the indoor assembly unit.
Thermal actuator rod
9. Install the sound absorbing layer on the outer side. Roll the layer of the sound absorbing material to match the air duct diameter.
The protecting paper layer must be outside. Insert the sound absorbing roll into the cartridge against stop.Mark the end of the sound
absorbing roll to be flush with the air duct edge and cut the excess.Insert the ready sound absorbing roll into the air duct.
10. Install the outer ventilation hood. The mounting sequence of the outer ventilation hood is described in the installation instruction
for the ventilation hood.
F112EN-02.indd 10