![Ventacity Systems VS1200 CMh/e Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/ventacity-systems/vs1200-cmh-e/vs1200-cmh-e_installation-and-operation-manual_865552011.webp)
11
Rev. 01.01
SPECIFICATIONS
2. SPECIFICATIONS
VS250 CMh/e S
PECIFICATIONS
Flow Rate
60 - 270 cfm / 102 - 459 m
3
/h
Increments: 15 cfm / 25.5 m
3
/h
Max. External Static Pressure
2.0 inch W.C. / 498 Pa
Exchanger Efficiency (AHRI 1060) HRV: 91.2% Sensible
ERV: 85.7% Sensible; 75.9% Latent; 82.3% Total
Temperature Conditions
Outdoor: -4
°
to 104
° F
/ -20
°
to 40
°
C
Ambient: 41
°
to 104
° F
/ 5
°
to 40
°
C
Max. Return Air Humidity
90%
Dimensions (L x D x W)
30.7” x 12.2” x 46.9” / 0.780 m x 0.31 m x 1.19 m
Shipping Dimensions (L x D x W)
39” x 18” x 59” / 0.99 m x 0.46 m x 1.5 m
Weight (Shipping)
HRV: 154 lbs / 70 kg (Shipping: 197 lbs / 89 kg)
ERV: 159 lbs / 72 kg (Shipping: 204 lbs / 93 kg)
Fans (EC, Variable Speed Control) Plastic Impeller; 3653 RPM; IP54
Filters
Outside Air: MERV13 (11.2 x 9.25 x 3.78 in. / 285 x 235 x 96 mm)
Return Air: MERV9 (11.2 x 9.25 x 3.78 in. / 285 x 235 x 96 mm)
Preheater
Integrated Preheater for Frost Prevention
Core Bypass
PID Bypass Damper for Temperature Control
Insulation & Thermal Conductivity 2” Foam @ 0.042 W/mK / 0.024 BTU/(hr ft
°
F); 0.8mm Galvanized Steel Inner/Outer Casing
Duct Connection
9.84” x 5.91” / 250 mm x 150 mm; Diameter 7.87” / 200 mm
Operation Modes
CAV, DCV, VAV, BMS, Economizer (Freecooling)
Certifications
TUV SUD (UL 1812, CSA 22.2 No. 113) Pending
Passive Haus: Pending
FCC Pending
Sensors
Temperature (10Kohm NTC Thermistors):
Outside Air, Supply Air, Supply Duct, Return Air, Exhaust Air
Pressure:
OA and RA Filter Pressure Drop
Pressure Differential of Supply to Atmosphere (VAV)
Optional Accessories
(Provided by Ventacity)
External Outside Air and Exhaust Air Damper Modules
External DX or WCO Postheater Modules
Internally Mounted CO2 Sensor (Room CO2 Sensor Recommendations Available)
External Condensate Pump
ELECTRICAL
Voltage
Phase
Power Supply
FLA – Max
MCA
MOP
De-Ice Preheater
Preheater Temp Rise
Maximum Power
per Fan
208 VAC
1
1.41 kW
6.8 A
8.2 A
10 A
1.14 kW
8.5
°
C
125 W (0.17 hp)
240 VAC
1
1.78 kW
7.4 A
9 A
10 A
1.51 kW
11.3
°
C
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0
50
100
150
200
250
300
100% FAN SPEED
External Static Pressure [in W
.C.]
Flow Rate [CFM]
60 – 250 CFM
0 – 2.0" W.C. ESP
FAN OPERATING RANGE
(recommended operating range)