Installation and Wiring Instructions for the VA100 SELV 12

 

Fan & Controller. 

  IMPORTANT: 
  READ THESE INSTRUCTIONS 
  BEFORE COMMENCING THE  
  INSTALLATION 

 
DO NOT install this product in areas where the following may be present or occur: 

  Excessive oil or a grease laden atmosphere. 

  Corrosive or flammable gases, liquids or vapours. 

• 

Ambient temperatures higher than 40°C or less than –5°C. 

• 

Possible obstructions which would hinder the access or removal of the Fan. 

 

SAFETY AND GUIDANCE NOTES 
A. 

All wiring to be in accordance with the current I.E.E. Regulations, or the 
appropriate standards of your country and 

MUST 

be installed by a suitably 

qualified person. 

B. 

The fan should be provided with a local isolator switch capable of 
disconnecting all poles, having a contact separation of at least 3mm. 

C. 

Ensure that the mains supply (Voltage, Frequency, and Phase) complies 
with the rating label. 

D. 

The fan should only be used in conjunction with the appropriate Vent-Axia 
products. 

E. 

It is recommended that the connection to the fan connector terminals is 
made with flexible cable. 

F. 

The transformer/controller should be sited away from direct sources of 
heat.  The transformer requires free air circulation and should be mounted 
securely to a joist in the roof void.  

G. 

Do not

 

cover the transformer/controller with insulation or other materials. 

H. 

When the fan is used to remove air from a room containing a fuel-burning 
appliance, ensure that the air replacement is adequate for both the fan and 
the fuel-burning appliance. 

I. 

The fan should not be used where it is liable to be subject to direct water 
spray for prolonged periods of time. 

J. 

Where ducted fans are used to handle moisture-laden air, a condensation 
trap should be fitted. Horizontal ducts should be arranged to slope slightly 
downwards away from the fan. 

K. 

This appliance is not intended for use by young children or infirm persons 
without supervision. 

L. 

Young children should be supervised to ensure that they do not play with 
the appliance. 

Содержание VA100

Страница 1: ...2 25 84 10E VA100SVLH12 25 81 12E VA100SVXH12 25 83 12F VA100SVXHT12 25 85 12C PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS VA100 SELV 12 RANGE FAN UNITS 1...

Страница 2: ......

Страница 3: ...only be used in conjunction with the appropriate Vent Axia products E It is recommended that the connection to the fan connector terminals is made with flexible cable F The transformer controller shou...

Страница 4: ...exposed to direct water spray e g from a shower head whether permanently fixed or movable 2 Site away from direct sources of heat Ambient temperature range 0 to 40 C Do not site in an area containing...

Страница 5: ...n 4 Repeat for the external grille sub frame Fix exterior grille into position with the louvres positioned downwards AFTER INSTALLATION ENSURE IMPELLER ROTATES FREELY B WIRING WARNING THE FAN AND ANCI...

Страница 6: ...sible that the humidity controller will make the fan run continuously until it has acclimatised to the environment As part of the installation process it is important to set adjust the humidity sensit...

Страница 7: ...FUSE Switched Fused Spur N 2 1 Controller L Fan SELV Supply 12V 50Hz Pullcord L N 3A UK LS N L N Fan Controller LS L N SELV Supply 12V 50Hz 3A UK Ls LS 0 12V N L 1 Phase Supply 220 240V 50Hz FUSE Swit...

Страница 8: ...tact your local supplier Vent Axia guarantees its products for two years from date of purchase against faulty material or workmanship In the event of any part being found to be defective the product w...

Отзывы: