PRODUCT FICHE 

For Residential Ventilation Units (Complying Commission Delegated Regulation (EU)         No 1254/2014) 

 
 
 
 
 

Name:

  

Vent

Axia

 

Vent

Axia

 

Vent

Axia

 

Vent

Axia

 

Model

 

ID

 

(Stock

 

Ref.)

 

:

 

Solo

 

Pro

 

P

 ‐ 

409159

 

Solo

 

Pro

 

T

 ‐ 

409160

 

Solo

 

Pro

 

HTP

 ‐ 

409161

 

Solo

 

Pro

 

TM

 ‐ 

409162

 

SEC

 

Class

 

F

 

F

 

E

 

E

 

SEC

 

Value

 

('Average')

 

13.97

 

15.72

 

26.23

 

26.23

 

SEC

 

Value

 

('Warm')

 

6.32

 

7.11

 

11.86

 

11.86

 

SEC

 

Value

 

('Cold')

 

27.32

 

30.75

 

51.31

 

51.31

 

Label

 

Required?

 

(Yes/No=Out

 

of

 

scope)

 

No

 

No

 

No

 

No

 

Declared

 

as:

 

RVU

 

or

 

NRVU/UVU

 

or

 

BVU

 

RVU

UVU

 

RVU

UVU

 

RVU

UVU

 

RVU

UVU

 

Speed

 

Drive

 

on/off

 

Single

 

Speed

 

on/off

 

Single

 

Speed

 

on/off

 

Single

 

Speed

 

on/off

 

Single

 

Speed

 

Type

 

HRS

 

(Recuperative,

 

Regenerative,

 

None)

 

None

 

None

 

None

 

None

 

Thermal

 

Eff:

 

[

 

(%),

 

NA(if

 

none)]

 

N/A

 

N/A

 

N/A

 

N/A

 

Max.

 

Flow

 

Rate

 

(m3/h)

 

86.40

 

86.40

 

86.40

 

86.40

 

Max.

 

Power

 

Input

 

(W):

 

(@Max.Flow

 

Rate)

 

17.00

 

17.00

 

17.00

 

17.00

 

LWA:

 

Sound

 

Power

 

Level

 

(dB)

 

47.52

 

47.52

 

47.52

 

47.52

 

Ref.

 

Flow

 

Rate

 

(m3/s)

 

0.02

 

0.02

 

0.02

 

0.02

 

Ref.

 

Pressure

 

Diff.

 

(Pa)

 

N/A

 

N/A

 

N/A

 

N/A

 

SPI

 

[W/(m3/h)]

 

0.28

 

0.28

 

0.28

 

0.28

 

Control

 

Factor

 

&

 

Control

 

Typology:

 

(CTRL/

 

Typology)

 

  

  

  

  

Control

 

Factor;

 

CTRL

 

1.00

 

0.95

 

0.65

 

0.65

 

Control

 

Typology

 

Manual

 

Control

 

Clock

 

Control

 

Local

 

Demand

 

Control

 

Local

 

Demand

 

Control

 

Declared:

 ‐

Max

 

Internal

 

&

 

External

 

Leakage

 

Rates(%)

 

for

 

BVUs

 

or

 

carry

 

over

 

(for

 

regenerative

 

heat

 

exchangers

 

only),

                                                                                                

&Ext.

 

Leakage

 

Rates

 

(%)

 

for

 

Ducted

 

UVUs;

 

N/A

 

N/A

 

N/A

 

N/A

 

Mixing

 

Rate

 

of

 

Non

Ducted

 

BVUs

 

not

 

intended

 

to

 

be

 

equipped

 

with

 

one

 

duct

 

connection

 

on

 

either

 

supply

 

or

 

extract

 

air

 

side;

 

N/A

 

N/A

 

N/A

 

N/A

 

Position

 

and

 

description

 

of

 

visual

 

filter

 

warning

 

for

 

RVUs

 

intended

 

for

 

use

 

with

 

filters,

 

including

 

text

 

pointing

 

out

 

the

 

importance

 

of

 

regular

 

filter

 

changes

 

for

 

performance

 

and

 

energy

 

efficiency

 

of

 

the

 

unit

 

N/A

 

N/A

 

N/A

 

N/A

 

For

 

UVUs

 

(Instructions

 

Install

 

Regulated

 

Supply/Extract

 

Grilles

 

Façade)

 

In

 

F&W

 

In

 

F&W

 

In

 

F&W

 

In

 

F&W

 

Internet

 

Address

 

(for

 

Disassembly

 

Instructions)

 

www.vent

axia.com

 

www.vent

axia.com

 

www.vent

axia.com

 

www.vent

axia.com

 

Sensitivity

 

p.

 

Var20/

20

 

Pa:

 

(for

 

Non

Ducted

 

Vus)

 

N/A

 

N/A

 

N/A

 

N/A

 

Air

 

Tightness

ID/OD

(m3/h)

 

(for

 

Non

Ducted

 

Vus)

 

N/A

 

N/A

 

N/A

 

N/A

 

Annual

 

Electricity

 

Consumption:

 

AEC

 

(kWh/a)

 

3.87

 

3.68

 

2.52

 

2.52

 

Annual

 

Heating

 

Saved:

 

AHS

 

(kWh/a)

 

  

  

  

  

AHS:

 

Average

 

13.97

 

15.72

 

26.23

 

26.23

 

AHS:

 

Warm

 

6.32

 

7.11

 

11.86

 

11.86

 

AHS:

 

Cold

 

27.32

 

30.75

 

51.31

 

51.31

 

 
 
 
 

 

Содержание Solo Pro HTP

Страница 1: ...ation and Wiring Instructions Stock Ref N Solo Pro P 409159 Solo Pro T 409160 Solo Pro HTP 409161 Solo Pro TM 409162 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Solo Pro IPX4 220 240V 50Hz ...

Страница 2: ... Phase complies with the rating label D The Fan should only be used in conjunction with the appropriate Vent Axia products E The fan should only be used in conjunction with fixed wiring F When the Fan is used to remove air from a room containing a fuel burning appliance ensure that the air replacement is adequate for both the fan and the fuel burning appliance G The Fan should not be used where it...

Страница 3: ...re the fan as described in Section B Wiring Adjust any settings as required see Section C Setup 8 Replace the PCB and inner covers and impeller 9 After installation ensure impeller rotates freely Replace the front panel WALL MOUNTING FIG 4 1 For wall mounting cut a 117mm diameter hole through the wall and insert the wall sleeve Slope the sleeve slightly downwards away from the fan Where necessary ...

Страница 4: ... TIMER SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION 1 Remove the fan grilles and PCB cover The product is factory set at 15 minutes approx The overrun period can be adjusted from 3 25 minutes by altering the pot on the control PCB 2 To REDUCE the operating time use a small screwdriver to turn the pot ANTI CLOCKWISE 3 To INCREASE the operating time use a small screwdriver to turn the pot C...

Страница 5: ...RD is switched into the off position the fan will deactivate The HTP model will return to the Auto sensing mode D SERVICING AND MAINTENANCE WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE 1 At intervals appropriate to the installation the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits 2 Carefull...

Страница 6: ...r 2 Remove the two screws as shown 3 For P and HTP models remove the pull cord clip L Switched Fused Spur 1 Phase Supply 220 240V 50Hz N L FUSE N N L 5 4 3 5A Fig 3 Solo Pro TM Visionex PIR Controller Please follow the fitting and wiring instructions for the Visionex PIR Controller for full installation instructions Solo Pro TM ...

Страница 7: ... together to release the impeller 5 Remove two screws as shown Fig 5 Wiring and settings Supply cable via side or rear Supply cable connections Secure Supply cable with Cable Clamp Adjust Timer overrun or Humidistat set point model dependant as shown ...

Страница 8: ...ogy Control Factor CTRL 1 00 0 95 0 65 0 65 Control Typology Manual Control Clock Control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs N A N A N A N A Mixing Rate of Non Ducted BVUs not intended to be equipped with one duct connection on either supply or extract ...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...lect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your original supplier or nearest Vent Axia Centre by post or personal visit Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and pro...

Отзывы: