INSTALLATION GUIDANCE 

1. 

The installer is responsible for the installation and electrical connection of the system on 

site. It is the responsibility of the installer to ensure that the equipment is safely and 
securely installed and left only when mechanically and electrically safe. 

2. All regulations and requirements must be strictly followed to prevent hazards to life and 
property, both during and after installation, and during any subsequent servicing and 
maintenance. 

3. Certain applications may require the installation of sound attenuation to achieve the 
sound levels required. 

4. The unit must not be connected directly to a tumble drier. 

5. The supply air must be drawn from the exterior of the property. 

6. The exhaust grille should be located at least 600mm away from any flue outlet. The inlet 
grille should  be located 2000mm away from any flue outlet. 

 

 

 

 

 

 

 

 

Disposal 

This product should not be disposed of with household waste. Please 
recycle where facilities exist. Check with your local authority for 
recycling advice 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание HR300

Страница 1: ...00 Through the wall Heat Recovery Ventilator Installation and Maintenance Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Stock Ref No HR300 3703...

Страница 2: ......

Страница 3: ...d by a suitably qualified person after completion 3 Ensure the mains supply voltage frequency and phase complies with the rating label 4 The unit should be provided with a local double pole fused spur...

Страница 4: ...stallation and during any subsequent servicing and maintenance 3 Certain applications may require the installation of sound attenuation to achieve the sound levels required 4 The unit must not be conn...

Страница 5: ...Contents Section Page 1 0 Introduction 5 2 0 Site Requirements 6 3 0 Installation 7 4 0 Electrical 9 5 0 Maintenance 10...

Страница 6: ...power consumption for the unit is 108w 4 The twin impeller and heat exchanger arrangement simultaneously supplies and extracts air while transferring heat from the stale exhaust airflow to the fresh...

Страница 7: ...ply is compatible with the rating label attached to the product 8 The unit must be sited such that the ambient temperature will not exceed 40 C 9 Do not site the appliance in the vicinity of excessive...

Страница 8: ...ect an approved electrical control arrangement for the HR300 unit above 2 After considering the site requirements Section 2 0 select a suitable site for the unit and controllers and work out the cable...

Страница 9: ...the two fixing screws provided NOTE Ensure the fixings DO NOT inhibit removal or replacement of the heat exchanger 4 Make good around the case 5 Fit the bezel on the inside to cover the making good b...

Страница 10: ...HR300 is supplied with a length of cable attached from the factory This can be extended with the use of 4 core cable as required 5 Connect the wires as shown in Fig 7 to a Switched fused spur or a co...

Страница 11: ...from rear of grille 6 Slide out the heat exchanger Fig 8 7 Wash the grille filter and heat exchanger in warm water using a mild detergent and dry thoroughly CAUTION Keep water away from all electrical...

Страница 12: ...4 months Clean cell replace filters the new filters will be supplied with 4 additional Timestrip indicators Note The above is the minimum requirement more frequent cleaning intervals may be needed dep...

Страница 13: ...Typology Central Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs 5 Inter...

Страница 14: ...Notes...

Страница 15: ...Notes...

Страница 16: ...ating label attached to the unit Has not been subjected to misuse neglect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE P...

Отзывы: