INSTALLATION GUIDANCE
1.
The installer is responsible for the installation and electrical connection of the system on
site. It is the responsibility of the installer to ensure that the equipment is safely and
securely installed and left only when mechanically and electrically safe.
2. All regulations and requirements must be strictly followed to prevent hazards to life and
property, both during and after installation, and during any subsequent servicing and
maintenance.
3. Certain applications may require the installation of sound attenuation to achieve the
sound levels required.
4. The unit must not be connected directly to a tumble drier.
5. The supply air must be drawn from the exterior of the property.
6. The exhaust grille should be located at least 600mm away from any flue outlet. The inlet
grille should be located 2000mm away from any flue outlet.