9
1 2
ON
1 2
ON
Fig.9. Boost speed selection
TIMER, HUMIDISTAT-TIMER AND
HUMIDISTAT-PULLCORD
MODELS ONLY
Max speed boost:
Dip switch 2 in the ‘OFF’
position.
15l/s speed boost:
Dip switch 2 should be in the
‘ON’ position.
Fig.6. Accessing the control settings
Fig.7. Removing the front grille panel for cleaning.
Dip switch
Fig.8. Trickle speed selection and T/HT/HP adjuster
pots
9l/s
= Remove Jumper Connector
6l/s
= Replace Jumper Connector
(factory set)
JP1 Jumper
Timer
adjustment
Humidistat
adjustment
Max =
15l/s =
Содержание Centra Lo-Carbon SELV HT
Страница 2: ...2...