Speed Adjustment 

The fan has three speeds which are selectable by changing the position of the jumper. The fan is factory set to 
Setting 3 - High speed. To change the speed setting, pull the jumper off the header pins and place back onto the 
desired position, see Fig14.  
Setting 1 is 

LOW SPEED 

Setting 2 is 

MEDIUM SPEED 

Setting 3 is 

HIGH SPEED 

 

 

Variable Speed Controller 

Speed adjustment for the basic version can also be achieved with the use of a speed controller (stock reference 
W300310). If a speed controller is used then the speed setting on the fan unit should be setting 3 – High Speed. 
Follow the Installation and wiring instructions for the speed controller unit to install the controller correctly. A 
variable speed controller should 

NOT 

be used with the timer version. 

 
C. 

OVER-HEATING PROTECTION.

 

 

The fan motor is fitted with Thermal Overload Protection. This is a one-shot thermal fuse. In the event of a fault 
condition the fan will be automatically switched off. If this occurs isolate the fan, and call your service engineer. 

 
D. 

SERVICING AND MAINTENANCE. 

 

WARNING: 

THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED  

FROM THE POWER SUPPLY DURING MAINTENANCE.

 

 

 
1.  At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build 

up of dirt or other deposits.  

 

The ACM In-Line Mixed Flow fan has sealed for life bearings, which do not require lubrication. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Dimensions(mm) 

100 125 150 160 200 

AØ 98 

122 

147 

159 

198 

BØ 178 

178 

200 

200 

220 

C 124 

124 

138 

138 

138 

D 298 

259 

307 

352 

300 

E 96 

96 

118 

118 

130 

F 168 

168 

192 

192 

145 

FIXING CTRS

 120  120  162  162  100 

FIXING CTRS

 153.5 153.5  178  178  180 

 

15 
 
 
 
 
 
 

Setting 1 
LOW SPEED 

Setting 2 
MEDIUM SPEED 

Setting 3 
HIGH SPEED 

Содержание ACM100 B

Страница 1: ...IONS ACM In Line MIXED FLOW FANS Stock Ref N ACM100 B 17104010D ACM100 T 17104020F ACM125 B 17105010D ACM125 T 17105020C ACM150 B 17106010C ACM150 T 17106020D ACM160 B 17107010B ACM160 T 17107020B ACM200 B 17108010C ACM200 T 17108020B Installation and Wiring Instructions 220 240V 50Hz IP44 ...

Страница 2: ...y and MUST be installed by a suitably qualified person B The Fan should be provided with a local double pole isolator switch having a contact separation of at least 3mm C Ensure that the mains supply Voltage Frequency and Phase complies with the rating label D The Fan should only be used in conjunction with the appropriate Vent Axia products E It is recommended that the connection to the fan conne...

Страница 3: ...d it should be fully extended to obtain the best results Position the fan at the highest point on the system with both ducting runs sloping downwards from this point The airflow direction is indicated on the rating label with an arrow pointing in the direction of the airflow In circumstances where an excessive amount of moisture is present in the air then a condensation trap should be installed Re...

Страница 4: ...e terminal box cover screws Fig 13 6 Ensure the impeller rotates and is free from obstructions Timer models cannot be used with a speed controller Timer Adjustment The fan must be wired to a remote switch e g light switch When switched ON the fan will operate at the selected speed and will continue to run for a preset time after the fan is switched OFF The timer is factory set at 15 minutes approx...

Страница 5: ...OT be used with the timer version C OVER HEATING PROTECTION The fan motor is fitted with Thermal Overload Protection This is a one shot thermal fuse In the event of a fault condition the fan will be automatically switched off If this occurs isolate the fan and call your service engineer D SERVICING AND MAINTENANCE WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPP...

Страница 6: ...ace Velocity m s Design Flow Rate N A N A N A N A N A Nominal External Pressure Δps ext in Pa 71 74 92 92 167 Internal Pressure Drop of Ventilation Components Δps int in Pa N A N A N A N A N A Additonal Internal Press Drop of Non Ventilation Comp Δps add Pa N A N A N A N A N A Static Eff of fans used in accordance with Regulation EU No 327 2011 TBC TBC TBC TBC TBC Declared Max Internal External Le...

Страница 7: ...A N A Face Velocity m s Design Flow Rate N A N A N A N A N A Nominal External Pressure Δps ext in Pa 71 74 92 92 167 Internal Pressure Drop of Ventilation Components Δps int in Pa N A N A N A N A N A Additonal Internal Press Drop of Non Ventilation Comp Δps add Pa N A N A N A N A N A Static Eff of fans used in accordance with Regulation EU No 327 2011 TBC TBC TBC TBC TBC Declared Max Internal Exte...

Страница 8: ...fective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instructions given with each unit Has not been connected to an unsuitable electricity supply The correct electricity supply voltage is shown on the product rating label attached to the unit Has not been subjected to misuse neglect or d...

Отзывы: