OPERATION
Fan Speed Control:
1)
Trickle Speed
: the fan runs at trickle speed, which is set by the potentiometer R10
between 15% and 100% speed.
2)
Boost Speed
: boost speed is activated by the LS input on terminal J1, and is set by
the potentiometer R9 between 15% and 100% speed
.
3)
Note
it is not possible to set boost speed lower than trickle speed.
MAINS & CONTROL WIRING CONNECTION
MAINTENANCE AND SERVICING
The EC Trickle/Boost Controller has no replaceable parts, if a fault develops return to the
manufacturer.