24
User Setup -
System Runtimes
To view, set, or reset System Runtimes, press the SETUP button, then press
MODE. Press MODE to advance to the desired setup step. Use the WARMER or
COOLER buttons to adjust the value of your selection. Press SETUP again to
leave the setup screens.
UV Lamp Runtime
(setup steps 11, 15)
Current UV Lamp Calendar Days (setup step 11) - This counter displays the
total number of calendar days that have elapsed since last reset to help the
user track UV lamp runtime. Press FAN to reset.
Set UV Lamp Calendar Days (setup step 15) - This timer allows the user to
specify the number of calendar days the UV Lamp will operate before the
“Replace UV Lamp” alert will be displayed. Press COOLER continuously
until
0
appears to disable this alert.
Humidifier Runtime
(setup steps 12, 16)
Current Humidifier Calendar Days (setup step 12) - This counter displays the
total number of calendar days that have elapsed since last reset to help the
user track the Humidifier run-time. Press FAN to reset.
Set Humidifier Calendar Days (setup step 16) - This timer allows the user
to specify the number of calendar days the Humidifier will run before the
“Service Humidifier” alert will be displayed. Press COOLER continuously
until
0
appears to disable this alert.