28
Setup Steps
Press the SETUP button, then press MODE repeatedly until the
desired setup step appears. Use the WARMER or COOLER buttons
to make selection. Press MODE to advance to the next step.
Press/hold MODE to go backwards to prior steps. Press SETUP to
leave the setup screens.
WARMER
COOLER
MODE
SETUP
Event Max Cool Setpoint*
(Setup Step 73)
Event Min Heat Setpoint*
(Setup Step 74)
Specifies the range of allowable setpoint adjustments to be enforced when any ADR
signal has been received from the utility. Since you might be paying more for energy
while an event is active, you can impose tighter limits on setpoint ranges that are only
enforced during the event.
Static Cool Setpoint*
(Setup Step 75)
Static Heat Setpoint*
(Setup Step 76)
Specifies the setpoints that will come into use during an event when the PRICE
DEPENDENT ACTION is set to OBSERVE STATIC SETPOINTS
Cool Setpoint Offset*
(Setup Step 77)
Heat Setpoint Offset*
(Setup Step 78)
Specifies how much the current setpoints in effect prior to an event will be altered
during an event when the PRICE DEPENDENT ACTION is set to OBSERVE SETPOINT
OFFSETS. The heat setpoint can be automatically lowered by 1 to 10 degrees while the
cool setpoint can be automatically raised by 1 to 10 degrees.