Venmar VJ70330SS Скачать руководство пользователя страница 9

7. REINSTALL GREASE FILTER

To reinstall the grease filter, align down filter tabs with slots in the hood. Press down the
metal latch tab, push filter into position and release. Make sure the filter is securely
engaged after installation. Close the hood front panel.

11. Drill both screw holes using a 5/16” drill bit through inner hood mounting holes. Insert 

the included drywall anchors into the drilled holes (one per hole). Secure the hood 
using 2 no. 8 x 1¼” screws with 2 washers.

6. INSTALL THE HOOD 

(CONT’D)

HD0294

I

NNER

H

OOD

M

OUNTING

H

OLES

12. Restore electrical power at service panel.

HD0252

8. LIGHT BULBS

This range hood requires two UL approved halogen bulbs (JC type, 12 V, 20 W).

To replace bulbs:
1. Gently push the rim upward and rotate to disengage the light bulb cover.

2. Replace with JC type, 12V, 20 W Max, G-4 base halogen bulb. 
3. Reinstall the light bulb cover by pushing the rim upward and rotating the light bulb 

cover until secure. 

WARNING

Make sure power is switched off at service panel before carrying out any
operation on the hood.

!

WARNING

In order to prevent the risk of personal injury, the halogen lamps must be
cooled down before removing them.

CAUTION

Do not touch replacement bulb with bare hands!

!

LIGHT BULB COVERS

HD0253

- 9 -

Содержание VJ70330SS

Страница 1: ... LEAVE THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGE 10 Venmar Ventilation Inc 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ON LINE AT www bnv ca For additional information visit www venmar ca INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ...when cooking at high heat or when cooking flaming foods i e Crêpes Suzette Cherries Jubilee Peppercorn Beef Flambé c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSON S IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE TH...

Страница 3: ...t it is recommended to wear safety glasses and gloves WARNING To reduce the risk of fire use only metal ductwork 6 ROUND DUCT ROOF CAP ROUND ELBOW 24 ABOVE COOKING SURFACE WALL CAP HOOD DECORATIVE FLUE HH0094A 2 PREPARE THE INSTALLATION Make sure that the following items are included 1 Hood 1 Hood Glass Panel 1 Decorative Flue Assembly lower and upper flues 1 Metal Air Outlet 1 Hood Mounting Brack...

Страница 4: ... cord exits from the hood see illustration at right Make sure this does not interfere with a mouting bracket fastening area or with the decorative flue where the flue touches the wall 3 WIRING INSTALLATION WARNING Electrical wiring must be done by qualified person s in accordance with all applicable codes and standards This range hood must be properly grounded Turn off electrical power at service ...

Страница 5: ... flue bracket point down Use the upper flue mounting bracket as a template to mark the position of its screws Remove the mounting bracket Drill both screw holes using a 5 16 drill bit Insert the included drywall anchors into the drilled holes one per hole Secure the upper flue bracket to the wall using 2 no 8 x 1 flat head mounting screws Make sure that the bracket is thight against the wall C L H...

Страница 6: ...o the top of the hood Remove all protective plastic film on the hood 2 Remove protective plastic film on the lower flue and install it over the hood 3 Insert each glass special flat head screw into their rubber spacer 6 INSTALL THE HOOD 6 WARNING Be careful when installing the decorative flue and hood they may have sharp edges HJ0010 HO0101 HO0102 ...

Страница 7: ...lm on the upper flue to free its both side slots and slide it inside the lower flue 6 Align the hood and center it above the hood mounting bracket previously installed in step 5 Gently lower the hood until it is hung to the hood mounting bracket Using 2 no 8 x 1 flat head screws secure the lower flue bracket shaded part in the illustration at right to the wall CAUTION Do not overtight the screws w...

Страница 8: ...e mounting bracket using 2 no 8 x 5 16 mounting screws 9 Remove the protective plastic film covering the upper flue 10 Remove grease filter in order to acces hood inner mounting holes First access grease filter by opening the hood front panel A Then remove the grease filter by pressing down on its metal latch tab and tilt filter downward B Set aside grease filter 6 INSTALL THE HOOD CONT D HJ0011 6...

Страница 9: ...OOD MOUNTING HOLES 12 Restore electrical power at service panel HD0252 8 LIGHT BULBS This range hood requires two UL approved halogen bulbs JC type 12 V 20 W To replace bulbs 1 Gently push the rim upward and rotate to disengage the light bulb cover 2 Replace with JC type 12V 20 W Max G 4 base halogen bulb 3 Reinstall the light bulb cover by pushing the rim upward and rotating the light bulb cover ...

Страница 10: ...ag soaked with warm water and mild soap or liquid dish detergent Always clean in the direction of original polish lines Always rinse well with clear water 2 or 3 times after cleaning Wipe dry completely You may also use a specialized household stainless steel cleaner Don ts Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt Use any harsh or abrasive cleansers Allow...

Страница 11: ...screws 4 Rubber spacer 1 HL0108 Not illustrated 3 1 2 4 5 6 7 8 REPLACEMENT PARTS AND REPAIRS In order to ensure your ventilation unit remains in good working condition you must use Venmar Ventilation Inc genuine replacement parts only Venmar Ventilation Inc genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards...

Страница 12: ...rvice provider offers service If in home service is not available the product will be repaired or replaced at Venmar Ventilation Inc s discretion by the nearest authorized service provider The unit removal and reinstallation works are under the customer responsibility and Venmar Ventilation Inc cannot be charged for them The duration of any implied warranty is limited to the 1 year period as speci...

Отзывы: