- 8 -

1) Delay switch

3) Master OFF/Filter maintenance switch/Heat detector

2) Start/Stop/Speed selection switches

4) Light switch

1

2

3

4

1.  Delay switch:

When a speed is selected, press the delay switch to activate the delay function.
The corresponding speed indicator light will start flashing to indicate this function
is activated. The fan will continue to operate for 5 minutes and will stop automatically.
To cancel the delay function, press the delay switch once again.

2.  Start / Stop / Speed selection switches:

Press the switch corresponding to the desired fan speed. The light indicates the
selected speed (from speed“1” for Silentsure™* mode to          for ’’Boost Mode’’).
To turn off the fan, press once more on the corresponding fan speed switch.

3.  Master Off / Filter maintenance switch / Heat detector: (Triple function switch)

a)  To turn Off the motor and the lights simultaneously, press the switch once.
b)  After 25 hours of operation, the filter maintenance light indicator will turn

itself on. This indicates that the filters and the blower wheel need to be
cleaned in order to maintain efficient operation of the unit. The indicator light 
will stay ON until the function is reactivated by pressing this switch for 3 seconds.

c)  The light indicator is used for the Smartvent™* function as well (see below).

Smarvent™*(on some models only):

When an excessively high temperature is detected, the detector takes control
over the blower and ensure that an appropriate ventilation is produced. The
controller is equipped with two detection levels.

Protected mode level 1

: When medium heat is detected, the blower sets

itself to speed 3, the corresponding light indicator

comes ON and the        indicator flashes.

Protected mode level 2

:  When a greater heat is detected, the blower then

sets itself to Boost mode, the corresponding light

indicator turns ON and the        indicator flashes.

The blower will remain ON until the heat is back to normal, it then returns to the speed
previously selected.

NOTE: In a case of range top grease fire (temperature exceeding 90°C), the 

protected mode will be deactivated to prevent fire propagation.

*TM in Canada only. US TM pending.

4.  Light switch:

The light switch allows three different lighting levels according to your needs. 
Use 

appliance

light bulbs (120V, 40W, A15 model).

WARNING

The protected mode can start the blower even if the hood is turned OFF.
In protected mode, it is impossible to turn the blower OFF with the push
buttons. If you must stop the blower, do it from the main electrical panel.

1 0

!

HC0001

ELECTRONIC CONTROL

11.  OPERATION

Always turn ON your hood before you begin cooking in order to establish an air flow
in the kitchen. Let the blower run for a few minutes to clear the air after you turn off
the range. This will help keep the whole kitchen cleaner and brighter.

Содержание Signature S1 Series

Страница 1: ...NLY INSTALLER LEAVE THIS MANUAL TO HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGE 7 READ AND SAVE THESE INSTRUCTIONS www venmar ventilation com 04521 rev A Venmar Ventilation Inc 550 Lemire Blvd...

Страница 2: ...the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSON S IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray...

Страница 3: ...al filter unit kit WARNING Identifies an instruction which if not followed might cause serious personal injuries including possibility of death 1 0 CAUTION Denotes an instruction which if not followed...

Страница 4: ...k top HH0013A Hood 3 PREPARE THE INSTALLATION Make sure that the following items are included Hood Filters Bag of parts including 1 wire clamp 5 1 2 double thread screws 2 wire connectors and 6 1 2 sc...

Страница 5: ...tion make sure the adapter fits easily in the duct If this hood replaces another hood please note that location of the air exhaust can vary from one manufacturer to another 5 Remove the filters Remove...

Страница 6: ...nd GREEN wire under GREEN ground screw DO NOT FORGET TO CONNECT THE GROUND WARNING Risk of electrical shock Electrical wiring must be done by qualified personnel in accordance with all applicable code...

Страница 7: ...Always rinse well with clear water 2 or 3 times after cleaning Wipe dry completely You may also use a specialized household stainless steel cleaner Don t Do not use any steel or stainless steel wool...

Страница 8: ...arvent on some models only When an excessively high temperature is detected the detector takes control over the blower and ensure that an appropriate ventilation is produced The controller is equipped...

Страница 9: ...maintenance or repairs made by other than Venmar Ventilation inc or c a faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is l...

Страница 10: ...SERVICE PARTS HL0015 10 3 1 2 5 4...

Страница 11: ...pair also for s s 01992 1 Mesh filters for 30 hood the pair 01989 1 Micromesh filters for 30 hood the pair 14131 4 2 Mesh filters for 36 hood unit 02070 1 Micromesh filters for 36 hood the pair 14132...

Страница 12: ...ITOR AUTO TRANSFORMER BULB 40W BULB 40W BULB 40W BULB 40W Signature S1x and S2x Models Signature S3x and S4x Models CONTROL BOARD J1 3 K1 NO K2 NC K1 NC LOGIC LOGIC REFERENCE GROUND K3 NC K2 NO K3 NO...

Отзывы: