background image

- 11 -

SERVICE PARTS

TECHNICAL SPECIFICATIONS

Ref.# Qty.  Description

Part Number

1       1     Light Diffuser

01752

1     30” clear glass

01832

2

1     36” clear glass

02049

1     30” tinted glass

01874

1     36” tinted glass

02050

1     White glass holder (the pair)

01991

3   

1     Almond / Biscuit glass holder (the pair)

01993

1     Black glass holder (the pair) (also for s/s)

01992

1     Mesh filters for 30” hood (the pair)

01989

1     Micromesh filters for 30” hood (the pair)

14131

4

2     Mesh filters for 36” hood (unit)

02070

1     Micromesh filters for 36” hood (the pair)

14132

5  

1     Adapter and damper

13296

1     Instruction manual

04521

Installation bag ((1) wire clamp, 

1       (6) screws # 6 x 1/2", (5) double thread screws

04281

and (2) wire connectors)

Transformer

120 VAC, 60 Hz

Bulbs  (A15)

2 x 40 W max.

Models:

S1x         S2x         S3x         S4x

Total power consumption

200 W      245 W     245 W     245 W  

cfm                                                       270          370      270/370  300/440

Содержание Signature S1 Series

Страница 1: ...NLY INSTALLER LEAVE THIS MANUAL TO HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGE 7 READ AND SAVE THESE INSTRUCTIONS www venmar ventilation com 04521 rev A Venmar Ventilation Inc 550 Lemire Blvd...

Страница 2: ...the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSON S IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray...

Страница 3: ...al filter unit kit WARNING Identifies an instruction which if not followed might cause serious personal injuries including possibility of death 1 0 CAUTION Denotes an instruction which if not followed...

Страница 4: ...k top HH0013A Hood 3 PREPARE THE INSTALLATION Make sure that the following items are included Hood Filters Bag of parts including 1 wire clamp 5 1 2 double thread screws 2 wire connectors and 6 1 2 sc...

Страница 5: ...tion make sure the adapter fits easily in the duct If this hood replaces another hood please note that location of the air exhaust can vary from one manufacturer to another 5 Remove the filters Remove...

Страница 6: ...nd GREEN wire under GREEN ground screw DO NOT FORGET TO CONNECT THE GROUND WARNING Risk of electrical shock Electrical wiring must be done by qualified personnel in accordance with all applicable code...

Страница 7: ...Always rinse well with clear water 2 or 3 times after cleaning Wipe dry completely You may also use a specialized household stainless steel cleaner Don t Do not use any steel or stainless steel wool...

Страница 8: ...arvent on some models only When an excessively high temperature is detected the detector takes control over the blower and ensure that an appropriate ventilation is produced The controller is equipped...

Страница 9: ...maintenance or repairs made by other than Venmar Ventilation inc or c a faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is l...

Страница 10: ...SERVICE PARTS HL0015 10 3 1 2 5 4...

Страница 11: ...pair also for s s 01992 1 Mesh filters for 30 hood the pair 01989 1 Micromesh filters for 30 hood the pair 14131 4 2 Mesh filters for 36 hood unit 02070 1 Micromesh filters for 36 hood the pair 14132...

Страница 12: ...ITOR AUTO TRANSFORMER BULB 40W BULB 40W BULB 40W BULB 40W Signature S1x and S2x Models Signature S3x and S4x Models CONTROL BOARD J1 3 K1 NO K2 NC K1 NC LOGIC LOGIC REFERENCE GROUND K3 NC K2 NO K3 NO...

Отзывы: