HRV CONSTRUCTO 1.5ES*

(

PART

 

NOS

 46110 

AND

 1601702) 

HRV CONSTRUCTO 2.0ES*

(

PART

 

NO

. 47110)

ERV CONSTRUCTO 2.0ES

(

PART

 

NO

. 47115)

HRV SOLO 1.5ES*

(

PART

 

NOS

 46720 

AND

 46725)

HRV SOLO 2.0ES*

(

PART

 

NO

. 47720)

* T

HESE

 

PRODUCTS

 

EARNED

 

THE

 ENERGY STAR

®

 

BY

 

MEETING

 

STRICT

 

ENERGY

 

EFFICIENCY

 

GUIDELINES

 

SET

 

BY

 

N

ATURAL

 R

ESOURCES

 C

ANADA

 

AND

 

THE

 US EPA. T

HEY

 

MEET

 ENERGY STAR 

REQUIREMENTS

 

ONLY

 

WHEN

 

USED

 

IN

 C

ANADA

.

INSTALLER MANUAL

READ AND SAVE THESE INSTRUCTIONS

RESIDENTIAL USE ONLY

20503 

REV

. 04

VB0175

VB0176

VB0170

I

MPORTANT

 

INFORMATION

 

FOR

 

THIS

 

UNIT

 

ABOUT

 

DRAIN

 

INSTALLATION

 

IN

 

COLD

 

CLIMATES

 

ON

 

PAGE

 12, 

SECTION

 3.8.

Содержание HRV CONSTRUCTO 1.5ES

Страница 1: ...PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY GUIDELINES SET BY NATURAL RESOURCES CANADA AND THE US EPA THEY MEET ENERGY STAR REQUIREMENTS ONLY WHEN USED IN CANADA INSTALLER MAN...

Страница 2: ...r connect directly to any appliances 8 Do not use to exhaust hazardous or explosive materials and vapors 9 When performing installation servicing or cleaning this unit it is recommended to wear safety...

Страница 3: ...5 2 EXHAUST DUCTED SYSTEM 9 3 5 3 SIMPLIFIED INSTALLATION 10 3 6 CONNECTING THE DUCTS TO THE UNIT 11 3 7 INSTALLING THE EXTERIOR HOODS 12 3 8 CONNECTING THE DRAIN 12 13 3 8 1 HRV UNITS 12 3 8 2 ERV UN...

Страница 4: ...CYCLES MINUTES EXTENDED DEFROST CYCLES CELCIUS C FAHRENHEIT F DEFROSTING OPERATION TIME BETWEEN EACH DEFROST CYCLES DEFROSTING OPERATION TIME BETWEEN EACH DEFROST CYCLES 5 23 10 60 10 30 15 5 10 30 1...

Страница 5: ...INCREASED LOW SPEED ELECTRICAL SUPPLY 120 V 60 HZ 120 V 60 HZ 120 V 60 HZ 120 V 60 HZ 120 V 60 HZ POWER CONSUMPTION 160 WATTS 195 WATTS 200 WATTS 160 WATTS 195 WATTS 17 432 mm 17 438 mm 6 152 mm Powe...

Страница 6: ...austed from the high humidity areas in the home such as bathrooms kitchen and laundry room Fresh air is supplied to the cold air return or the supply duct of the furnace If required bathroom fans and...

Страница 7: ...panel on the side of the unit Close to an exterior wall so as to limit the length of the insulated flexible duct to and from the unit Close to a drain If no drain is close by use a pail to collect run...

Страница 8: ...e choice for the main exhaust duct End branches Each end branch will have to transport an air flow of 70 cfm 140 divided by 2 Table above indicates a 5 duct Recommended air flow 75 cfm maximum air flo...

Страница 9: ...point 3 5 1 above FRESH AIR DISTRIBUTION 3 5 2 EXHAUST DUCTED SYSTEM AS ILLUSTRATED IN SECTION 2 2 There are two methods for connecting the unit to the furnace METHOD 1 SUPPLY SIDE CONNECTION Cut an o...

Страница 10: ...accordance with all applicable codes and standards Please refer to your local building code CAUTION If using Method 2 make sure the furnace blower operation is synchronized with the unit operation Se...

Страница 11: ...collar Pull down the vapor barrier shaded part in illustrations below over the outer ring to cover it completely Fasten in place the vapor barrier using the port strap included in unit parts bag To d...

Страница 12: ...CAUTION A drain tubing included must be installed for all HRV units For ERV units it is not required however it is recommended for climates where the outside temperature typically remains below 25 C 1...

Страница 13: ...ns off and the booting sequence is done NOTE No command will be taken until the unit is fully booted 4 1 2 SETTING EXTENDED DEFROST The unit is factory set to normal defrost In cold region it may be n...

Страница 14: ...ve been made insert the terminal connector in the electrical compartment front face NOTE For information about the operation of the wall controls refer to the user guide VD0278 TERMINAL CONNECTOR LOCA...

Страница 15: ...CTOR THERMOSTAT TERMINALS FOUR WIRES TWO WIRES heating only FURNACE 24 VOLT TERMINAL BLOCK TWO WIRES COOLING SYSTEM NO C NC I OC OL Y R G B W R G Y W R Y R G Y C THERMOSTAT TERMINAL 4 WIRES 2 WIRES he...

Страница 16: ...ional see notes 3 5 J14 4 J14 5 J14 6 J14 7 J14 8 J14 9 J14 10 Override switch optional see notes 3 4 Field wiring remote control see notes 3 4 ICP BK Y R G W W nc Motor capacitor Fan motor GN GN BN B...

Страница 17: ...m Adjust the fresh air balancing damper until the FRESH air flow is approximately the same as the EXHAUST air flow If FRESH air flow is less than EXHAUST air flow then go back and adjust the exhaust b...

Страница 18: ...2 00601 4 00887 2 00601 4 14 Diffuser 60822 60822 60822 60822 60822 60822 15 Filter kit 60800 60800 60800 60799 60800 60800 60800 16 Core 60802 60801 60803 16582 60802 60801 60803 17 Door latches and...

Страница 19: ...rol LED flashes GREEN The unit damper has been blocked or broken integrated control LED flashes AMBER and unit is OFF Motor won t turn Clean the exterior air intake port Replace the unit thermistor Ch...

Страница 20: ...ction 6 Wiring Diagram Check if the fuse F1 is intact If all the readings correspond to the right voltage values the circuit board is not defective If one or both readings are different change the cir...

Отзывы: