MA-SE-HE00-01-11 Manual HEMA eng rev11
Page
4
of
8
2.
THREE-WIRE CONNECTION
Connect 13.8 Vdc supplying coming from control panel to the dedicated terminals:
-RIC negative; +RIC positive. (+C trigger must be jumped to +RIC ); RES negative trigger for flash reset.
Note: by default, DIPSWITCH N°2 is set in OFF N°6 OFF, POSITIVE-MISSING TRIGGER
3.
HEMA LSP MODEL WIRING
Connect 13.8 Volt supplying coming from control panel to the dedicated terminals:
-RIC negative; +RIC positive; +C positive-missing trigger; RES negative trigger for flash reset.
Note: by default, DIPSWITCH N°2 is set in OFF position, POSITIVE-MISSING TRIGGER
Only in HEMA LSP model, terminal M9 must be jumpered to terminal M10 TAMPER A.P.
4.
OPTICAL INDICATION OF SYSTEM STATUS (MOMENTARY OR PERMANENT ON-OFF)
If a positive is given to terminal STI (System status) all LEDs of the flashing light make 3 flashes (ON);
If the positive is removed, all LEDs light on steady for 5 seconds (OFF) and the complete sounder test is launched (remote test).
By default, DIPSWITCH N°4 is set in OFF position (MOMENTARY ON-OFF)
DIPSWITCH N°4 in ON position (MOMENTARY ON-OFF) and 1 LED keeping on flashing as long as positive tension = 0V is given to terminal STI.
5.
SOUNDER TIMING
By default, timing is 3 minutes (DIPSWITCH N°1 in OFF position) and it can be modified into 8 minutes.
+13.8 Vdc and OUTDOOR SOUNDER
TRIGGER
TAMPER LINE
GND 0 Vdc
ALARM CONTROL PANEL
SOUNDER
+13.8 Vdc
GND 0 Vdc
OUDOOR SOUNDER TRIGGER
TAMPER LINE
ALARM CONTROL PANEL
SOUNDER
FLASH RESET
TRIGGER
FLASH RESET
TRIGGER