CONNECTION SCHEME

TERMINALS CONNECTIONS

–1

NEGATIVE POWER SUPPLY OV GND

+2

POSITIVE POWER 13.8V

c3

SOUNDER CONTROL

4

ON/OFF - ALARM SYSTEM STATUS NOTICE

5

FLASH RESET / BLOCK SPEAKER INPUT

6

ANOMALY OUTPUT. OPEN COLLECTOR 
0V = NO ANOMALY

7

N.C. SELF-PROTECTION AND ANTI-FOAM

8

N.C. SELF-PROTECTION AND ANTI-FOAM

A

RED RGB LED INPUT

B

GREEN RGB LED INPUT

C

BLUE RGB LED INPUT

D

WHITE RGB LED INPUT

ANOMALY OUTPUT

 

The sounder is managed by a microcontroller able to check battery recharge, battery status and the speaker; in 

case of anomaly, open collector terminal (6) opens.

Every 22 hours, the microcontroller automatically performs the battery test, notified by LD4 fast flash and other tests

every 10 sec. In case of anomaly, LD4 LED blinks according to the table below.

If the sounder is 

correctly powered

, the anomaly output (terminal no. 6) 

usually stays at 0V

 (current max 50mA). In

case a test performed 

is not passed

, the anomaly output 

disconnects from ground and becomes free

Notification of last anomaly, indicated by LED LD4 is reset to zero only if a command is given to terminal no.4 or c3. 

To launch the remote battery test, send a pulse to terminal no. 5 with sounder on rest mode. This way, a 30-seconds 

test runs.

 

ANOMALY TYPE

LD4 LED

Speaker interruption (test performed every 10 s)

1 flash

No recharge current (recharge current is lower than 12V)
(test performerd every 10 s)

2 flashes

Battery is disconnected (test performerd every 10 s)

3 flashes

Battery voltage is low (recharge is lower than 10V)
(test performed every 10 s) 

4 flashes

Battery low-capacity, deterioration
(test performed every 22 hours)

5 flashes

No anomalies

OFF

Test battery in progress

Fast

FLASH RESET / BLOCK SPEAKER INPUT

 

With DIP6 in OFF, terminal 5 works as block speaker. With DIP6 in ON, terminal 5 works as reset flash: the flashing 
unit activates with sounder trigger and deactivates with terminal 5. During normal operation, a command to terminal 
5 activates battery test that lasts 30 seconds. 

Содержание GIUDECCA

Страница 1: ...EN TECHNICAL MANUAL GIUDECCA ...

Страница 2: ...HNICAL MANUAL 2 IMPORTANT SAFETY INSTRUCTIONS READ THE FOLLOWING SECTION CAREFULLY AND STORE IT WARNING Explosion risk if the battery is replaced with a wrong type High sound pressure risk of hearing loss ...

Страница 3: ...ion at box drilling Holes must be drilled only where indicated otherwise internal components may be improperly housed Drill only where strictly necessary MAX 5 mm Flush Drillable area Spirit level ALTO UP MAX 5 mm Flush Drillable area Spirit level ALTO UP Drillable area DIRECTIONS FOR A CORRECT MOUNTING Zona forabile Zona forabile a 1 To ensure a correct functioning of the tamper maximum installat...

Страница 4: ...CCA with high luminosity and low consumption multicolor LED flashing light anti opening tamper protection programmable sound and timing microprocessor self test of battery and speaker with anomaly negative output programming of sounder polarity command and system ON OFF immediate or permanent optical indication of ON OFF system electronic circuit protected against polarity inversion and resin trop...

Страница 5: ...se a test performed is not passed the anomaly output disconnects from ground and becomes free Notification of last anomaly indicated by LED LD4 is reset to zero only if a command is given to terminal no 4 or c3 To launch the remote battery test send a pulse to terminal no 5 with sounder on rest mode This way a 30 seconds test runs ANOMALY TYPE LD4 LED Speaker interruption test performed every 10 s...

Страница 6: ... 3 in ON sound is INCREASING DECREASING DIP 4 SYSTEM STATUS OPTICAL SIGNALISATION ON OFF IMMEDIATE AND PERMANENT Dip switch 4 in OFF instantaneous ON OFF situation DEFAULT SETTING Dip switch 4 in ON instantaneous ON OFF situation with blue LED flashing intermittently while trigger is given to terminal 4 By giving a command to terminal no 4 the LEDs of the sounder blink in red 3 times ON and all an...

Страница 7: ...mA 10 mA Consumption in stand by 15mA Consumption from control inputs 0 5 mA Vc 12V 0 3 mA Vc 0V Open collector 50 mA Max Fundamental frequency 2 100 Hz Maximum acoustic power 105 dB A 1 m LED flashing unit life 1 000 000 flashes Working temperature conditions From 30 to 65 C Timing Settable 3 8 minutes Control panel command 2 or 3 wires Battery capacity 12V 2 3Ah Pb Size 151x316x124 H x W x D Rec...

Страница 8: ...e legale e operativa Headquarters Via del Lavoro 10 30030 Salzano VE Italy Tel 39 041 5740374 Fax 39 041 5740388 info venitem com www venitem com UNI EN ISO 14001 UNI EN ISO 9001 AZIENDA CERTIFICATA MA SE GIUD 01 02 ...

Отзывы: