-  Read and understand the users'manual before operating and mounting the air handling unit with heat recovery, hereinafter 

referred as the unit.

-  While mounting and operating the unit consider the requirements of the present user's manual as well as requirements of all 

applicable local and national building and electrical codes and standards.

-  Read carefully the warnings contained in the manual to make yourself aware of the safety rules!
-  Non-compliance with the rules and warnings stated in the user's manual may result in a personal injury or the unit damage.
-  Read the user's manual carefully and keep it as long as you use the product.
-  In case of transferring operation of the unit to another person provide the user manual..

Symbol designation used in the manual:

MOUNTING SaFTEy PRECaUTIONS

Disconnect the unit from 

power supply before mounting 

and repair operations.

The unit must be grounded!

Do not operate the unit

 beyond the specified 

temperature range. 

Do not use damaged electric 

equipment and conductors for 

electric connections.

Follow all applicable electrical 

safety rules while operating and 

mounting the unit.

Unpack the unit carefully.

Unauthorized power cable 

length modification is not 

allowed

Keep heating and other 

devices away from the unit 

power cable.

WARNING !

DO NOT !

Содержание Medium Comfort

Страница 1: ...www veneco ventilation be Installaton manual Medium Comfort 07 2015 V 1 1 EN...

Страница 2: ...User s manual Medium Comfort 2 Elek Trends Productions nv Rue des Bengalis 4 B 7700 Moeskroen Tel 32 0 56 48 15 90 Fax 32 0 56 48 15 91 info veneco ventilation be www veneco ventilation be...

Страница 3: ...ements p4 2 Introduction p6 3 Use p6 4 Delivery set p6 5 Designation key p6 6 Main technical data p7 7 Design and operating logic p8 8 Mounting and set up p9 9 Connection to power mains p13 10 Unit co...

Страница 4: ...sult in a personal injury or the unit damage Read the user s manual carefully and keep it as long as you use the product In case of transferring operation of the unit to another person provide the use...

Страница 5: ...containers with water for example vases on the unit Do not sit on the unit and do not put any objects on it Do not damage the power cable while operating the unit Do not put any objects on the power c...

Страница 6: ...able air exchange by means of mechanical ventilation in houses offices hotels cafes conference halls and other residential and public premises as well as extract air heat recovery for warming up of fr...

Страница 7: ...to air ductworks The unit design is regularly improved so some models may slightly differ from those ones described in this manual Speed 1 2 3 Voltage 50 60 Hz 1 100 240 Power W 4 2 9 6 15 4 Total uni...

Страница 8: ...3 C 37 4 F the heat exchanger freezing danger is registered In this case the supply fan is turned off and the unit operates in exhaust mode only After the heat exchanger is warmed up and the freezing...

Страница 9: ...outer ventilation hood that prevents ingress of foreign objects inside the unit If the building s wall thickness is above 500 mm prepare two extra 125 mm air ducts of required length PAPER MASTER PLAT...

Страница 10: ...kit somewhat lower to ensure the minimum required slope 3 Before mounting the master plate press the perforated holes to remove the master plate fragments and prepare holes for the air ducts 5 Insert...

Страница 11: ...ting those to the 8 mm holes Install the heat exchanger and close the front panel Install the outer ventilation hood NB Medium Comfort on outer side of the building to prevent ingress of large foreign...

Страница 12: ...panel Route the cable in the wall to the speed switch installation site Attach the back panel to the wall through the fastening openings Connect the control cable to the speed switch following the wir...

Страница 13: ...9 CONNECTIONTO POWER MAINS DISCONNECT THE UNIT FROM POWER MAINS PRIOR TO ANY ELECTRIC INSTALLATION OPERATIONS CONNECT THE UNIT TO A CORRECT INSTALLED SOCKET WITH A GROUNDED TERMINAL ANY INTERNAL CONNE...

Страница 14: ...eaning of the unit surfaces and its components of dust and cleaning or replacement of the unit filters To remove dust use a soft brush cloth or a vacuum cleaner Do not use water abrasive detergents so...

Страница 15: ...e commences on the day of purchase or invoice date of the product with a recognized dealer and ends after the guarantee period as described below The ELEKTRENDS guarantee is valid when the unit is use...

Страница 16: ...ETP nv Blauwfazantjesstraat 4 B 7700 Moeskroen Tel 32 0 56 48 15 90 Fax 32 0 56 48 15 91 info veneco ventilation be1 www veneco ventilation be...

Отзывы: