background image

T-2

Part #1169256 

 

 

 

 

 

 

 

 

 

 

               09/2008

SandenVendo America, Inc.

NEW EQUIPMENT WARRANTY

V21 VENDING MACHINES

Distributor - United States / Canada /  Mexico

I.  This warranty benefi ts each current owner of a V21 vending machine, whether that owner is the original purchaser 
or a transferee.

II.  The SandenVendo America, Inc. Company warrants each part of each new vending machine for a period of fi fteen 
(15) months from the date of shipment, to be free from defects in material and workmanship. This Warranty DOES NOT 
include light bulbs, fl uorescent tubes, fuses, fi nish or operating supplies. 

III.  The hermetically-sealed refrigeration system used in machines designed to vend bottles, cans, and aseptic cartons 
is warranted to be free from defects in materials and workmanship for six (6) years, provided the hermetically-sealed 
portion of the system has not been opened or damaged.  This six (6) year warranty DOES NOT include fan motors, 
temperature controls, capacitors, overload switches or starting relays.

IV.  Electronic control boards, LED displays and Vend motors, are warranted against defects in material and 
workmanship for fi ve (5) years. 

V.  Return authorization is required to qualify for warranty replacement. All requests for returns must be in writing or via 
phone, within the warranty period, and accompanied by a record of the cabinet model and serial number of the machine. 
Freight carrier return tickets will only be issued to the machine owner for refrigeration system returns. This warranty is 
voided when the serial number of a machine is missing. If a return is found to be inoperative due to defects in material 
and/or workmanship, we will, at our option, make necessary repairs or furnish a reconditioned or new replacement part 
or refrigeration system at no charge.

VI.  “Return Material Tags” indicating cabinet model, machine serial number and explanation of defect must accompany 
all returned parts or machines. “Return Material Tags” will be furnished upon request. On-site inspection of defective 
parts, at SandenVendo America, Inc. option, may be used to facilitate credit approval or the replacement of parts.

VII. SandenVendo America, Inc. will pay normal transportation charges on refrigeration systems and parts replaced 
under this warranty. If special handling or premium transportation is requested, those charges will be assumed by the 
machine owner.

VIII.  Any parts and/or refrigeration systems replaced during the warranty period are warranted for the remaining time 
on the original warranty

IX.  This warranty DOES NOT apply to machines located outside the United States, Canada, and Mexico, reconditioned 
equipment, equipment sold “as is”, or components designed to work on electric currents other than 110v/120hz 60 
cycle, as specifi ed on the serial tag.

X.  Title and risk of loss pass to the machine owner on delivery of the vending machine, replacement parts and/or 
refrigeration system to the common carrier. All loss and damage claims are the responsibility of the machine owner and 
must be fi led with the delivering carrier.

XI.  This warranty DOES NOT include any service guarantee, either explicit or implied, nor will it extend to cover 
incidental or consequential damages resulting from purchaser or third party negligence, accident, vandalism, or an act 
of God.

XII.  SandenVendo America, Inc. reserves the right to make design changes, additions to, and improvements upon any 
of our product without incurring any obligation to incorporate same on any product previously manufactured.

XIII.  This warranty is in lieu of all other express warranties or other obligations or liabilities on our part, and we  
neither assume nor authorize any person to assume for us, any other obligation for liability in connection with the sale 
of said machines or parts thereof. EXCEPT AS SPECIFICALLY PROVIDED HEREIN, THERE ARE NO WARRANTIES 
GIVEN, EITHER EXPRESS OR IMPLIED, AND ALL OTHER WARRANTIES, INCLUDING SPECIFICALLY BUT 
WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, ARE 
HEREBY EXPRESSLY DISCLAIMED.

Содержание V21

Страница 1: ...Vendo V21 Manual for Identified Equipment Vendo P N 1124557 Rev B Chameleon SandenVendo America Inc 10710 Sanden Drive Dallas Texas 75239 800 344 7216 FAX 800 541 5684...

Страница 2: ...I Part 1169256 09 2008 CHAMELEON TABLE OF CONTENTS...

Страница 3: ...G 11 PROGRAMMING SECTION Pages P 1 P 12 12 4 PROGRAMMING Page P 2 SET UP AND CODE DESCRIPTION Pages P 3 P 12 12 4 WIRING DIAGRAMS Page P 12 TRADE CABINET SECTION Pages C 1 C 17 READING A PARTS LIST P...

Страница 4: ...III Part 1169256 09 2008 TROUBLESHOOTING Pages T 1 T 12 VENDO WARRANTY Pages T 2 PARTS RETURN PROCEDURE Page T 3 TROUBLESHOOTING GUIDE Pages T 4 T 11...

Страница 5: ...S 1 Part 1169256 09 2008 CHAMELEON SAFETY SECTION...

Страница 6: ...tions along with the service manual when installing or servicing the vendor We strongly recommend a similar commitment to safety by every servicing organization Only properly trained personnel should...

Страница 7: ...he floor surface Ideally no adjustment will be necessary and the leveling legs will be flush with the bottom of the vendor A spirit level is a useful aid to level the vendor When the outer door is ope...

Страница 8: ...S 4 Part 1169256 09 2008...

Страница 9: ...lt meter or test light determine which of the receptacle s power contacts is the live contact A Connect one probe to the receptacle s earth contact B Connect the second probe to the left or upper powe...

Страница 10: ...fter any door adjustment the floating quicker lock assembly should align itself automatically The latch assembly is adjustable To adjust loosen the latch bracket mounting screws raise or lower the lat...

Страница 11: ...covers and ground wires in place Plug equipment into outlets that are properly grounded and polarized where applicable and protected with fuses or circuit breakers All electrical connections must be d...

Страница 12: ...udden movement to escape mechanical action can result in contact with live circuits and vice versa It is therefore doubly important to maintain maximum clearances from both moving parts and live circu...

Страница 13: ...rnings noted in the electrical hazards section These warnings refer to the potential hazards associated with electrical power and moving parts Always maintain maximum clearances from electrical and mo...

Страница 14: ...performing maintenance tests or repairs All testing of sealed refrigeration systems must be done by trained personnel who are familiar with the systems and pressures involved B Physical Protection The...

Страница 15: ...ition WARNING SandenVendo America Inc EQUIPMENT HAS BEEN PROVIDED WITH APPROPRIATE PROTECTIVE DEVICES TO PROTECT AGAINST THE POSSIBILITY OF OVERHEATING AND FIRE AS A RESULT OF EQUIPMENT OR COMPONENT F...

Страница 16: ...IONS AND MODIFICATIONS CONTINUED WARNING THIS APPLIANCE MUST BE EARTHED IMPORTANT The wires in the main leads are colored in accordance with the following code 110v 120v 220v 240v Green Green and Yell...

Страница 17: ...e product or money To warn of the danger involved in tipping shaking or rocking the vending machine a decal has been designed to be affixed to vending machines One such decal is applied on the vending...

Страница 18: ...ines India Sanden International Singapore Pte Ltd Sanden House 25 Ang Mo Kio St 65 Singapore 569062 The Republic of Singapore Tel 65 482 5500 Fax 65 482 1697 Taiwan Sanden International Taiwan Corp No...

Страница 19: ...xico IMI Cornelius de Mexico S A de C V Manual Dublan No 35 Col Tacubaya Deleg Miguel Hidalgo C P 11870 Mexico Tel 52 55 5272 7904 Fax 52 55 5273 5949 Central America SandenVendo America Inc 10710 San...

Страница 20: ...S 16 Part 1169256 09 2008 NOTES...

Страница 21: ...G 1 Part 1169256 09 2008 CHAMELEON GENERAL INFORMATION...

Страница 22: ...boards and whether or not coinage is installed 20 oz PET capacity may vary based on the shape and size of the bottle 12 oz can capacities are listed using a 4 deep set up MODEL V21 721 V21 821 V21 62...

Страница 23: ...through the refrigeration compartment The refrigeration system requires rear to front air circulation for proper operation C POWER SUPPLY CONNECTION CAUTION DO NOT USE AN EXTENSION CORD The vendor s p...

Страница 24: ...IGERATED VENDING MACHINE 239L FIGURE 1 NOTE The Model number of the vending machine is located on the top left hand corner of the serial plate Do Not use the BASIC UNIT number The BASIC UNIT number is...

Страница 25: ...pening built into the coin insert Apply instruction label to area shown as needed by the vendor FLAVOR LABELS INSTALLATION In Figures 3 4 corresponding styles are indicated by A B C D or E notations I...

Страница 26: ...evaporator area LOADING INSTRUCTIONS BASIC LOAD SET UP see Figure 6 on next page The V21 machine is capable of vending a variety of products For specific information refer to the product set up label...

Страница 27: ...AN 7 0 TALL PRODUCT STEP FORWARD TALL PRODUCT MORE THAN 7 0 TALL PRODUCT STEP BACK SMALL DIAMETER PRODUCT SETTING Small diameter products less than 2 5 such as 500 ML water bottles require the use of...

Страница 28: ...haft It is also a means to provide feedback to the controller to determine when the motor has reached maximum clockwise and counterclockwise positions GATE P N 1122871 The gate holds product above the...

Страница 29: ...G 9 Part 1169256 09 2008 FIGURE 7...

Страница 30: ...ations change slightly when the column s depth setting is changed With the single depth setting one purchase is made and the bucket is reloaded With the double depth setting two purchases are made bef...

Страница 31: ...G 11 Part 1169256 09 2008 FIGURE 9...

Страница 32: ...G 12 Part 1169256 09 2008 NOTES...

Страница 33: ...P 1 Part 1169256 ECN 52202 08 2010 CHAMELEON VEC 12 4 Programming Section...

Страница 34: ...tton on the Main Control Board and press until Diagnostics appears Use selection button 2 or 3 to navigate through the modes The Modes are as follows Diagnostics Coin Payout Tube Fill Test Mode Cash D...

Страница 35: ...umn jog a column display test selection switches and relays 1 At Test Mode press Button 4 Display will Test Mode Vending 2 Press Button 2 or 3 to scroll to desired column 3 Press Button 4 to vend a If...

Страница 36: ...xit sub modes Cash Data This Mode allows you to retrieve historical information regarding the money accepted by the vendor To clear the individual selection cash data you must have the MIS Auto Reset...

Страница 37: ...scroll through the depth settings 1 4 5 Press Button 4 to save your new depth setting 6 Press Button 1 to exit mode Con guration There are various options that you can turn ON OFF The options are Mult...

Страница 38: ...be returned after the completion of the vend Deny Escrow ON The validator will stack all bills received OFF The validator will not stack the bills rather it will hold them in escrow until a vend is c...

Страница 39: ...assign ashing or unassign not ashing or steady columns 7 Press Button 1 Display reads Save 8 Press Button 4 to save 9 Press Button 1 twice to exit the mode Set Program Password Allows the operator to...

Страница 40: ...ange current setting The current setting will begin to ash 3 Press Button 2 or 3 to change current setting 4 Press Button 4 to save current setting Lighting If the Timing Features in the Con guration...

Страница 41: ...splay reads Degree Setting 3 The display will show the current degree scale Celsius or Fahrenheit 4 Press Button 4 and the degree scale will begin to ash 5 Press Button 2 or 3 to choose setting 6 Pres...

Страница 42: ...owing information Start Time When the machine turns off Start Days Stop Time When the machine turns back on Stop Days Selections Discount Allows you to program the machine to discount beverages at reg...

Страница 43: ...P 11 Part 1169256 08 2010 Return Exits the programming mode and returns the vendor to stand by...

Страница 44: ...2 13 1 15 16 17 18 YEL VIO GRY PNK RED BRN ORN TAN WHT BLU BLK WHT DS WHT DS WHT VS1 SHIELD VS1 WHT VS2 SHIELD VS2 1 2 3 5 6 7 8 9 10 11 12 13 1 15 16 17 18 GRN GRN D O O R C A B I N E T D O O R C A B...

Страница 45: ...P 13 Part 1169256 08 2010...

Страница 46: ...C 1 Part 1169256 09 2008 CHAMELEON CABINET PARTS...

Страница 47: ...rt numbers See pages C 4 and C 5 The example below will show how the parts are listed in the parts lists 1 VEND MOTOR ASSEMBLY This is the main assembly name and any replaceable parts will be indented...

Страница 48: ...C 3 Part 1169256 09 2008 Purposely left blank...

Страница 49: ...C 4 Part 1169256 09 2008 HARDWARE LIST...

Страница 50: ...C 5 Part 1169256 09 2008...

Страница 51: ...C 6 Part 1169256 09 2008...

Страница 52: ...24 13 LATCH BRACKET 1 1123675 14 NUT RETAINER HOUSING 1 1123689 15 NUT SEGMENT 3 1033085 16 SPRING 1 389690 17 CAP 1 1111988 18 SIDE DECAL 2 19 STACK SUPPORT 1 1123018 20 TOP HINGE 1 2000805 03 21 BRA...

Страница 53: ...C 8 Part 1169256 09 2008...

Страница 54: ...1 1123003 1123003 3 BACK SPACER ASSEMBLY 10 1123047 1 1123047 4 MOTOR HARNESS 1 1122918 1122918 MOTOR HARNESS W PRE COOL 1 1124065 1124065 5 LOWER RETAINER 10 1124868 1124868 6 TOP STACK STRAP 1 1122...

Страница 55: ...C 10 Part 1169256 09 2008...

Страница 56: ...122820 2 FRONT SPACER 10 1122814 3 VEND BUCKET 10 1122815 4 CAN CLIP 10 1122856 5 PRODUCT SPACER 2 4 DIA AR 1122928 6 GATE 10 1122818 7 E CLIP GATE 10 V801080 8 SPRING 10 390326 9 GATE LINK 10 1122819...

Страница 57: ...C 12 Part 1169256 09 2008...

Страница 58: ...32 5 1 1124421 16 CONDENSER DUCT 1 1122413 17 FAN MOTOR CONDENSER 115V 1 1121770 18 FAN MOTOR CLIP CONDENSER 1 V42323 19 BASE REFRIGERATION 1 1122470 20 START RELAY PART OF ASSY 513506066 1 21 OVERLOA...

Страница 59: ...C 14 Part 1169256 09 2008...

Страница 60: ...NO 1 POWER BOX HOUSING 1 1148515 2 RELAY 2 1128801 3 CLAMP 1 324099 3 4 CORDSET 1 1124281 5 TRANSFORMER 1 1111201 6 FUSEHOLDER 1 387966 50 7 0 8 AMP FUSE NOT SHOWN 1 1053864 8 POWER HARNESS 1 1123444...

Страница 61: ...porator Fan Harness Connects the evaporator fans to the power distribution box X X X 1123444 Power Distribution Harness Input for 110v service cord and output to compressor evaporator fans control boa...

Страница 62: ...C 17 Part 1169256 09 2008 NOTES...

Страница 63: ...TD 1 Part 1169256 09 2008 CHAMELEON Door Parts...

Страница 64: ...TD 2 Part 1169256 09 2008 5 3 3 4 7 2 6 8 11 15 16 1 18 19 20 21 14 13 12 17 AE S S R K K D K D Y K AK AJ 10 9 Y CHAMELEON TRADE DOOR...

Страница 65: ...VE 1 388271 388271 D 8 BUTTON ASY ROUND CHAMELEON 8 1149374 1149374 9 PLASTIC NUT 8 1073538 1073538 10 SELECTION SWITCH 8 368299 368299 11 BRACKET SIGN FACE 2 1149404 1149404 12 BALLAST 1 1127052 1127...

Страница 66: ...TD 4 Part 1169256 09 2008 2 3 4 5 1 10 11 12 13 15 17 19 16 18 16 20 9 8 7 6 D F U F F H H K K K F K F 14 K F F...

Страница 67: ...8 1143498 F 7 COIN INSERT CHUTE 1 1121066 1121066 U 8 ASY COOIN RETURN LEVER 1 1143372 1143372 F 9 DOOR BUMPER 2 1036912 1036912 10 DELIVERY HOPPER ASSEMBLY 1 1149325 1149325 D K 11 LAMP 17W T 8 24 2...

Страница 68: ...HANDLE 1 1002392 3 PIN STUD 1 387601 4 LOCK STUD QUICKER LOCK 1 1049724 5 SPRING 1 389691 6 E RING RETAINER 3 388589 7 HEX WASHER 1 387600 8 SPRING HEAVY 1 389691 9 FLAT WASHER 1 387718 10 T HANDLE FL...

Страница 69: ...TD 7 Part 1169256 09 2008...

Страница 70: ...ESCRIPTION QTY REQ PART NO PART NO 1 INNER DOOR ASSEMBLY 1 134302 103 134302 104 2 RAIN SEAL INNER DOOR 7 1 1111732 2 1111732 2 3 INNER DOOR SEAL 1 1075678 1075678 1 4 UPPER PRODUCT RETAINER ASSEMBLY...

Страница 71: ...TD 9 Part 1169256 09 2008 NOTES...

Страница 72: ...M 1 Part 1169256 09 2008 CHAMELEON MAINTENANCE...

Страница 73: ...hin 24 to 48 hours of burnout This will prevent damage to the ballast D Check the product temperature for proper cooling E Check the evaporator drain for obstruction water in the evaporator area must...

Страница 74: ...eaning procedure listed above in A D SCRATCH REMOVAL Remove or minimize hairline scratches and minor abrasions by using any good quality automobile polish Test product before using E LEXAN SIGNS To cl...

Страница 75: ...condenser at the condenser the heat is dissipated into the surrounding air The liquid refrigerant changes from a liquid to a vapor and back to a liquid again This change of state allows the refrigera...

Страница 76: ...nd compresses it increasing both pressure and temperature The compressor forces the compressed vapor out through the discharge line and into the condenser The condenser fan pulls air through the conde...

Страница 77: ...69256 09 2008 DISCHARGE SIDE VAPOR HIGH PRESSURE COMPRESSOR SUCTION 50 110 VAPOR CONDENSER FAN LIQUID DRIER LIQUID CONDENSER ACCUMULATOR EVAPORATOR LOW PRESSURE CAPILLARY RESTRICTION TUBE EVAPORATOR F...

Страница 78: ...It removes water and solid particles from refrigerant liquid One side of the drier is connected to the outlet line of the condenser the other side is connected to the capillary tube going to the evap...

Страница 79: ...M 8 Part 1169256 09 2008 FIGURE 2...

Страница 80: ...en the compressor motor reaches operating speed the starting relay opens and breaks the starting circuit THERMAL OVERLOAD SWITCH INCLUDED IN ASSEMBLY P N 513506066 The thermal overload switch is mount...

Страница 81: ...M 10 Part 1169256 09 2008 NOTES...

Страница 82: ...T 1 Part 1169256 09 2008 CHAMELEON TROUBLESHOOTING...

Страница 83: ...aterial Tags will be furnished upon request On site inspection of defective parts at SandenVendo America Inc option may be used to facilitate credit approval or the replacement of parts VII SandenVend...

Страница 84: ...art or accessory REFRIGERATION UNIT RETURN PROCEDURE 1 All refrigeration units returned must be accompanied by a material return tag P N 1122826 Tag must clearly state the reason for the return and th...

Страница 85: ...isplayed error code either the next existing detailed error code summary level error code or the nonE message will be displayed respectively 9 If selection button three Return is pressed the controlle...

Страница 86: ...blockage is found replace changer CrCH Changer check sum incorrect reported by changer Turn power switch off wait at least five seconds then turn on Manually clear the error If error does not clear re...

Страница 87: ...or is being used check for rC or bC errors If there is no rC or bC error 1 Check changer harness 2 Replace changer Turn power switch off Wait at least five seconds Turn power switch on If there is a r...

Страница 88: ...the path Clean acceptor or contact dealer Coin changer is improperly tuned if tunable Contact manufacturer for tuning Defective control board Replace test control board Always accepts coins but gives...

Страница 89: ...echanical Error Check for correct operation of the motor gate link bucket and gate Wrong product vending upon selection Misload by vendor loader Ensure that all product within each column is the same...

Страница 90: ...8888 s on the LED Defective LED Replace LED and or harness Defective control board Replace control board Refrigeration Refrigeration unit will not run even at the specific temperature No power or ins...

Страница 91: ...d Temperature setting too low Adjust set point in control board Defective temperature sensor Replace the temperature sensor Defective control board Replace the board Excessive noise Fan blade hitting...

Страница 92: ...door switch Defective control board Replace the board Heater runs but product freezing up Defective heater Replace the heater assembly Poor air flow Make sure that nothing is sitting in front of the h...

Страница 93: ...T 12 Part 1169256 09 2008 NOTES...

Отзывы: