Set Point Temperature
Sensor Reading
Degree Setting
Fan Energy Mode
Periodic Defrost Mode
To change the set point temperature:
1. Press Button 4 when the display reads “Refrigeration.”
2. The display will read “Set Point XX” with the current setting displayed.
3. To change the setting press Button 4 and the current set point temperature will begin to
fl
ash.
4. Press Button 2 or 3 to increase or decrease the set point.
5. Press Button 4 to save changes.
6. Press Button 1 twice to exit and return “Refrigeration” on display.
To display the temperature:
1. Press Button 4 when the display reads “Refrigeration.”
2. Press Button 2 or 3 until the display reads “Sensor Reading.”
3. Press Button 4 and the current temperature will be shown in Fahrenheit or in Celsius.
4. Press Button 1 twice to exit and return the display to “Refrigeration.”
To change the degree scale:
1. Press Button 4 when the display reads “Refrigeration.”
2. Press Button 2 or 3 until the display reads “Degree Setting.”
3. The display will show the current degree scale (Celsius or Fahrenheit).
4. Press Button 4 and the degree scale will begin to
fl
ash.
5. Press Button 2 or 3 to choose setting.
6. Press Button 4 to save setting.
7. Press Button 1 twice to exit and return the display to “Refrigeration.”
To change the Fan Energy Savings mode:
1. Press Button 4 when the display reads “Refrigeration.”
2. Press Button 2 or 3 until the display reads “Fan.”
3. The display will read “Fan X” with the current setting displayed.
4. To change the setting press Button 4 and the current Fan mode will begin to
fl
ash.
5. Press Button 2 or 3 to increase or decrease the Fan mode.
6. Press Button 4 to save changes.
7. Press Button 1 twice to exit and return the display to “Refrigeration.”
To change the Periodic Defrost Mode:
1. Press Button 4 when the display reads “Refrigeration.”
2. Press Button 2 or 3 until the display reads “Periodic Defrost.”
3. The display will show it on or off.
4. Press Button 4 and the setting value will
fl
ash.
5. Press Button 2 or 3 to choose your setting.
Refrigeration:
If ‘Timing Features’ in Con
fi
guration Mode are ‘Off’, you will only have access to the following
features:
Содержание V21
Страница 2: ...I Part 1169256 09 2008 CHAMELEON TABLE OF CONTENTS...
Страница 5: ...S 1 Part 1169256 09 2008 CHAMELEON SAFETY SECTION...
Страница 8: ...S 4 Part 1169256 09 2008...
Страница 20: ...S 16 Part 1169256 09 2008 NOTES...
Страница 21: ...G 1 Part 1169256 09 2008 CHAMELEON GENERAL INFORMATION...
Страница 29: ...G 9 Part 1169256 09 2008 FIGURE 7...
Страница 31: ...G 11 Part 1169256 09 2008 FIGURE 9...
Страница 32: ...G 12 Part 1169256 09 2008 NOTES...
Страница 33: ...P 1 Part 1169256 ECN 52202 08 2010 CHAMELEON VEC 12 4 Programming Section...
Страница 43: ...P 11 Part 1169256 08 2010 Return Exits the programming mode and returns the vendor to stand by...
Страница 45: ...P 13 Part 1169256 08 2010...
Страница 46: ...C 1 Part 1169256 09 2008 CHAMELEON CABINET PARTS...
Страница 48: ...C 3 Part 1169256 09 2008 Purposely left blank...
Страница 49: ...C 4 Part 1169256 09 2008 HARDWARE LIST...
Страница 50: ...C 5 Part 1169256 09 2008...
Страница 51: ...C 6 Part 1169256 09 2008...
Страница 53: ...C 8 Part 1169256 09 2008...
Страница 55: ...C 10 Part 1169256 09 2008...
Страница 57: ...C 12 Part 1169256 09 2008...
Страница 59: ...C 14 Part 1169256 09 2008...
Страница 62: ...C 17 Part 1169256 09 2008 NOTES...
Страница 63: ...TD 1 Part 1169256 09 2008 CHAMELEON Door Parts...
Страница 66: ...TD 4 Part 1169256 09 2008 2 3 4 5 1 10 11 12 13 15 17 19 16 18 16 20 9 8 7 6 D F U F F H H K K K F K F 14 K F F...
Страница 69: ...TD 7 Part 1169256 09 2008...
Страница 71: ...TD 9 Part 1169256 09 2008 NOTES...
Страница 72: ...M 1 Part 1169256 09 2008 CHAMELEON MAINTENANCE...
Страница 79: ...M 8 Part 1169256 09 2008 FIGURE 2...
Страница 81: ...M 10 Part 1169256 09 2008 NOTES...
Страница 82: ...T 1 Part 1169256 09 2008 CHAMELEON TROUBLESHOOTING...
Страница 93: ...T 12 Part 1169256 09 2008 NOTES...