![Vendo SVE DL6 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/vendo/sve-dl6/sve-dl6_programming-manual_4040284028.webp)
Instructions for programming SVE01 Board
functions
26
© SandenVendo Europe SpA
04 MDB max cashless credit
Here you can set the maximum credit that the coinage accepts for the key.
05 MDB Changer Keypad
Activate the button to dispense the coins you find on the coin mechanism
OFF = Not activated
ON = Enabled
06 MDB Correct change value
This parameter must be set to the minimum value of the coins that the coinage can
contain in the tubes to give the rest.
07 MDB Low change equation (*)
This parameter defines the equation of the tubes used to determine the situation of
little rest. The combination of empty status takes on the exact state of the rest:
A is the lowest value reported in the coin tubes.
D is the highest value reported in the coin tubes.
0 : TUBE A and TUBE B and TUBE C and TUBE D
1 : TUBE A or TUBE B or TUBE C
2 : TUBE A only
3 : TUBE B only
4 : TUBE C only
5 : TUBE D only
6 : TUBE B or TUBE C or TUBE D
7 : TUBE A and TUBE B or TUBE C
8 : TUBE A and TUBE B or TUBE D
9 : TUBE A and TUBE C or TUBE D
10 : TUBE B and TUBE C or TUBE D
11 : TUBE A and TUBE D or TUBE C
12 : TUBE B and TUBE D or TUBE A
13 : TUBE A or TUBE C
14 : TUBE A or TUBE B and TUBE C
15 : TUBE A or TUBE B
08 MDB Low change level (*)
This number will be deducted from the number of tubes reported by the coin
mechanism to calculate (based on the equation of low change) the exact status of
change
09 MDB Bill Accepted 1(*)
This parameter allows you to set the bills to be accepted under normal condition of
sales (refer to "MDB Coin Accepted1" for explanation)
10 MDB Bill Accepted 2(*)
This parameter allows you to set the bills to be accepted under normal condition of
sales (refer to "MDB Coin Accepted1" for explanation)
11 MDB Bill Acc.Low Change 1(*)
This parameter allows you to set the bills to be accepted under low change
condition (refer to "MDB Coin Accepted1" for explanation)