4 2 2 5 1 3 3 R e v C
POWER CORD
Loosen the (4) screws fixing the connection box cover, remove
the cover and park on (2) screws as shown in Fig 11.
The power cord and GFCI can be removed from its housing, the
cover can then be replaced and secured.
Keep the power cord secured on the center back of the cabinet
until the vendor is placed into its final location to avoid damage
to the cord.
POSITIONING & LEVELING VENDOR
Position the vendor in its place of operation within 6 ft (183cm) from the
power outlet or receptacle. Check that the ‘swing door’ has clearance on
the left side to allow sufficiently to service/load the trays, see Fig 12.
Leave at least 4” (10cm) inches between the back of vendor for air
circulation.
All levelers must touch the floor. The vendor must be level for proper
operation for the coins and to correctly align the ‘swing’ and pull-out
doors.
Adjust the four (4) leg levelers on the cabinet legs to make the cabinet
level front-to-back and left-to-right, use a spirit level or similar to verify.
IMPORTANT
GROUNDING (EARTHING) & ELECTRICAL
Consult local, state, and federal codes and regulations before installing the vendor.
Before connecting the vendor, the integrity of the main electrical supply must be checked for
correct polarity, presence of ground (earth) and the correct voltage. These checks should be
repeated at six-month intervals with the routine safety electrical testing of the vendor itself.
If the receptacle is not properly grounded or polarized, contact a licensed electrician to
correctly polarize and/or ground the receptacle to ensure safe operation.
For proper operation of any equipment utilizing electronically controlled components, the equipment should be placed on a
dedicated, noise-free circuit and be properly polarized and grounded. Use of a surge conditioner/suppressor is recommended for
locations where electrical noise is present.
MAIN POWER SWITCH
Plug the power cord into the power outlet.
Open the vendor ‘Pull-Out’ door and turn ON the main power switch located on the face of the
power panel within inside the cabinet, see Fig 13.
Fig 11. Loosen the (4) screws to Access the Power Cord
Fig 13. Main Power Switch
Fig 12. Clearance for Loading Left Side