COMBI VENDOR • 3532
| 30
REMOVING THE REFRIGERATION SYSTEM
CAUTION:
Always disconnect power source BEFORE servicing
.
1. Turn off Main Power Switch and unplug
vendor power cord from wall outlet.
2. Remove the bottom tray but not rails.
3. Locate the cabinet control harness and
temperature sensor harness on the top right
of the refrigeration unit. Unplug the
connector to refrigeration unit, the
temperature sensor 2, and the evaporator
fan. See Figure 10g. Remove harness from
any retaining clips mounted on the
refrigeration unit.
4. Remove the two (2) screws on the front
spacer bracket. Pull on the top edge of the
front spacer bracket and swing it down to
remove it.
5. Remove the front retaining bracket by
removing the four (4) screws. See Figure
10h.
6. Remove the mounting screw securing the
metal wedge from the left side of the
refrigeration unit. Pry and remove the metal
wedge.
7. Pull the refrigeration unit halfway out of the
cabinet. Unplug the condenser fan harness
from the back of the refrigeration unit. Pull
the refrigeration unit out.
Figure
10
g
.
Unplug Harness
Figure 10
h
. Remove Front Brackets
NOTE:
All gaskets must seal
tightly to the back and right side of the cabinet when
installing the refrigeration unit back into the cabinet.
PREVENTIVE MAINTENANCE
CAUTION:
Always disconnect power source BEFORE cleaning or
servicing.
ONCE A MONTH
CLEAN CABINET INTERIOR
Wash with a mild detergent and water, rinse and dry thoroughly. Odors may be eliminated
by including baking soda or ammonia in the cleaning solution. Plastic parts may be cleaned
with a quality plastic cleaner.
The vend mechanisms must be kept clean. Any build-up can cause the mechanisms to
malfunction.
Do not get the cleaning solution on electrical components.
To insure proper vending keep delivery box area free of dirt and sticky substances.
CLEAN CABINET EXTERIOR
Wash with a mild detergent and water, rinse and dry thoroughly. Clean occasionally with a
quality car wax. Plastic exterior parts may be cleaned with a quality plastic cleaner.