background image

 

2019.10 

 

  1 / 8

 

 

 

INDEX 

1.

 

INTRODUCTION ..................................................................................................................................... 1

 

2.

 

GENERAL IDENTIFICATION OF DEVICE TYPE and MODEL ............................................................... 2

 

3.

 

TECHNICAL DATA ................................................................................................................................. 2

 

4.

 

TECHNICAL SPECIFICATIONS ............................................................................................................. 3

 

5.

 

INSTALLATION ....................................................................................................................................... 3

 

6.

 

OPERATION ........................................................................................................................................... 7

 

7.

 

HANDLING & STORAGE ........................................................................................................................ 7

 

8.

 

MAINTENANCE ...................................................................................................................................... 7

 

9.

 

FAULT DETECTION ............................................................................................................................... 7

 

10.

 

WARRANTY ........................................................................................................................................ 8

 

11.

 

ANNEX ................................................................................................................................................ 9

 

11.1.

 

Annex-1: Electrical Wiring Diagrams ................................................................................................ 9

 

 

1.  INTRODUCTION 

Before  operating  VENCO  branded  VD-EX  Wall  Mounted  Axial  Type  Exproof  Fans,  please  examine 

carefully the instruction manual and keep it. Do not use devices as a workbench or a storage area. VENCO 
VD-EX  Wall  Mounted  Axial  Type  Exproof  Fans  can  only  be  operated  in  conditions  of  intended  design  and 
technical specifications. 

 

 

 

 

 

 

DEVICES TO BE USED IN DANGEROUS ENVIRONMENTS ARE DESIGNED 
SPECIFICALLY FOR THE ENVIRONMENT TO BE SUITABLE FOR THE OFFICIAL 
REGULATIONS. FALSE USE, INCOMPATIBLE CONNECTION OR OTHER SMALL 
CHANGES MAY HAZARD PRODUCT RISK. 

 

BEFORE OPERATING READ THIS MANUAL and KEEP IT IN REACH OF A SERVICE 
PERSONNEL. 

 

THIS FAN CAN ONLY BE OPERATED IN CONDITIONS OF INTENDED DESIGN AND 
TECHNICAL SPECIFICATIONS. OTHERWISE THE RESPONSIBILITY BELONGS TO 
INSTALLER. 

Содержание VD-EX

Страница 1: ...CE USER MANUAL WALL MOUNTED EXPROOF AXIAL FANS VENCO Havaland rma ve Makina San ve Tic A 2004 Cad No 5 45400 OSB Turgutlu MAN SA T RK YE Tel 0090 236 332 5070 Fax 0090 236 332 5030 www venco com tr ve...

Страница 2: ...d keep it Do not use devices as a workbench or a storage area VENCO VD EX Wall Mounted Axial Type Exproof Fans can only be operated in conditions of intended design and technical specifications DEVICE...

Страница 3: ...assified as a place in which an explosive atmosphere consisting of a mixture with air or flammable substances in the form of gas vapour or mist is likely to occur in normal operation occasionally Zone...

Страница 4: ...y whether the fan wheel runs freely Before installation check the minimum air gap between the blade tip and the housing according to the following table The fan can be mounted parallel to the wall wit...

Страница 5: ...2019 10 4 8 Sample pictures of the assembled device Fan Diameter VD EX Min mm Max mm 315 0 6 1 6 355 0 8 1 8 400 1 2 450 1 25 2 25 500 1 4 2 4 560 1 4 2 4 630 1 58 2 58 710 2 6 3 6...

Страница 6: ...fan has direct contact with the outside air a plastic damper must be used on the outer side of the outer wall to stop this contact for lightning protection ALL ELECTRICAL CONNECTIONS SHALL BE DONE ACC...

Страница 7: ...ar position after rotation When dismantling the crate to gain access to the fan assembly care should be taken to avoid injury from sharp edges nails staples splinters etc 8 MAINTENANCE Periodically ch...

Страница 8: ...full load current specified on the motor nameplate Rotate the motor shaft by hand Investigate any sound of grinding noises internal chaffing rubbing or stiffness Any observed defect may indicate that...

Страница 9: ...2019 10 8 8 ANNEX 11 1 Annex 1 Electrical Wiring Diagrams Motor connection without termic Motor connection with termic...