User Manual Digital Heat Regulators
English
[ALR] alarm menu
Notes:
(13) This is the status taken on by the outputs in probe alarm condition (see note 11)
(14) This value is added to or subtracted from the set point defined for the maximum
or minimum alarm respectively
(15) If “yes”, the acoustic signal of the key and the buzzer are enabled in alarm
condition. If “no”, both of these are disabled.
(16) If “yes”, the type of alarm is also displayed during its timing.
If “no”, the type of alarm is displayed only at the end of the timing
[DSP] display menu
Notes:
(17) Parameter active only if the operating mode permits
(18) This value is added to the measurement to compensate for imprecision
(19) This is the resolution at which the measurement is displayed:
0.1 if “HI” or 1.0 if “LO”
(20)
Important:
if the measurement unit is modified, the parameters set are not con
verted automatically, but have to be re-calibrated.
Labels of
parameters that
can be modified
Description
Parameter
values
default notes
SUA
Output status in probe
alarm condition
-
0
3
0
(13)
LOA
Minimum alarm shift
degrees 0.1
100
50
(14)
HIA
Maximum alarm shift
degrees 0.1
100
50
(14)
DFA
Alarm differential
degrees 0.1
100
2
TRA
Alarm activation delay time
min
0
200
0
SOU
Buzzer enable
-
no
yes
no
(15)
EAC
Alarm message in timing enable -
no
yes
no
(16)
min max
unit
Labels of
parameters that
can be modified
Description
Parameter
values
default notes
LO1
Lower limit of set-point 1
degrees -99
HI1
-99
HI1
Upper limit of set-point 1
degrees LO1 999
999
LO2
Lower limit of set-point 2
degrees -99
HI2
-99
(17)
HI2
Upper limit of set-point 2
degrees LO2 999
999
(17)
SOF
Probe calibration offset
degrees -50 +50
0.0
(18)
RIS
Resolution displayed
-
HI
LO
HI
(19)
UNI
Temperature measurement
-
C
F
C
(20)
FIL
Measurement filter
-
no
yes
yes
(21)
min max
unit
En
gl
is