- 54 -
User Manual - CRONO.X programmable thermostat
English
MAXIMUM AND MINIMUM DAILY TEMPERATURE
CRONO.X
stores the external and internal minimum and maximum values
measured over the day
(external temperature only if an external sensor is
provided).
• To view these values just press (for the minimum temperature) or (for the
maximum temperature)
This function is available when in Automatic and off mode, but not when
in manual mode.
• To set the minimum or maximum readings to zero, just hold down or for at
least 3 seconds until the display reads “
---
”
The maximum value will be identifi ed as “
KI
”, the minimum as “
Lo
”.
LOW BATTERY LEVEL INDICATOR
When the
batteries
are
about to be dead the display will start to fl ash.
When in this condition, relay changeover is not guaranteed: it is therefore advisable
to replace the batteries (cfr. page 60 “BATTERY REPLACEMENT”).