15
STEP 4:
Select ID
Press NEXT until the desired ID appears. The existing types are: DEPTH (depth), PRES
(pressure), TEMP (temperature), COND (conductivity), SPD (speed), RATE (pulses per
minute, etc.), and ANGL (angle). When the desired ID is shown on the display, press the
ENTER key.
STEP 5:
Select Units
Press NEXT until the desired unit for the ID type appears and then select ENTER. The units
are labels only and do not convert the slope and intercept from one unit to another. For
example, to change the units from meters to feet, the slope and intercept must be converted
and entered in the VR60 receiver as feet. The available Units are shown in the table below:
AVAILABLE UNITS
DEPTH
m
ft
fath
meters
feet
fathoms
PRES
psi
bars
kg/M
pounds per square inch
bars
kilograms per square meter
TEMP
“C
“F
°C (degrees Celsius)
°F (degrees Fahrenheit)
COND
mmho
R
milli mhos per centimeter
conductivity Ratio
SPEED
mph
knts
m/S
rpm
miles per hour
knots per hour
meters per second
revolutions per minute
RATE
ppm
Hz
mSec
pulses per minute
cycles per second
milliseconds
STEP 6:
Select Slope and Intercept
The slope and intercept calibrated for each transmitter (listed in the Transmitter
Specifications manual for the order) must be entered. The display will show:
S: XXX I: YYY
T n (Y/N)
where
n
is the transmitter number,
XXX
the slope and
YYY
the intercept. Press YES if the
data shown is correct, or NO to enter the correct slope and intercept. If NO is selected, a
prompt will appear on the display requesting the slope. Enter the slope without the decimal
point and select ENTER. For example, a slope of 25.6 is entered as 2 5 6. The display then