max 3 sec
1 sec
2
3
RESET
24V
1
min 5 sec
KUX 110
VELUX
®
12
ENGLISH
V
A
S 4
5
4
3
6
0
-2
01
9
-0
2
1
The products connected can be
reset by removing the cover of the
power supply unit and pressing the
RESET button for at least 5 seconds.
The connected products will run
briefly back and forth in random
order to indicate that they are ready
for pairing.
Note:
Registration (
2
and
3
) must
now be completed within the next
10 minutes.
If a non-functional wall switch must be replaced or if the wall switch cannot find certain products, the products can be
prepared for registration by resetting them manually.
Note:
Reset products cannot be operated until they have been registered in the wall switch again.
Important:
The wall switch type must match the relevant product(s).
Setup of wall switch KLI 311/312/313 to operate electrical products
connected to VELUX INTEGRA
®
power supply unit KUX 110
2
Press PAIR button on the wall
switch for 1 second.
3
Press the STOP key and then the
DOWN key within 3 seconds.
The products can now be operated
with the wall switch.