background image

 

PMLCDL 

V. 02 – 08/07/2015 

©Velleman nv 

USER MANUAL 

1.

 

Introduction 

To all residents of the European Union 

Important environmental information about this product 

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm 
the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken 
to a specialized company for recycling. This device should be returned to your distributor or to a local 

recycling service. Respect the local environmental rules. 

If

 

in doubt, contact your local waste disposal authorities. 

Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If 
the device was damaged in transit, don't install or use it and contact your dealer. 

2.

 

Applications 

Voltmeter, thermometer, PH meter, dB meter, Watt meter, current meter, capacitance meter, Lux meter, LCR 
meter, other industrial & domestic uses 

3.

 

Operation 

If needed, add proper voltage dividers (not included) and decimal point wire jumper: 
(RA and RB are 1/2 W 0.5% metal film resistors) 

 

Max. voltage to be measured 

Proper Voltage Divider 

Decimal Point 

200 mV 

Short-circuit P3 - P0 

20 V 

Disconnect wire jumper in RB. 

RB = 9.9M

:

 ; RA = 100k

:

 

Short-circuit P2 - P0 

200 V 

Disconnect wire jumper in RB. 

RB = 9.99M

:

 ; RA = 10k

:

 

Short-circuit P3 - P0 

500 V 

Disconnect wire jumper in RB. 

RB = 9.999M

:

 ; RA = 1k

:

 

 

x

 

Connect an appropriate power supply to the panel meter (depending on the model, see Technical 
Specifications). 

x

 

For ranges other than 200mV, generate an input voltage of exactly half the measuring range (e.g. 100V for 
200V range) and carefully adjust the semi-fixed resistor R2 until you obtain the same reading on the 
display. 

x

 

Connect the input voltage to be measured to +Vin and -Vin. The input voltage should be DC only. 

4.

 

Technical Specifications 

display 

3 1/2-digit LCD 

input sensitivity 

200 mV FS 

power supply 

9 VDC (7 - 12 VDC) 

decimal point selection 

with wire jumper 

automatic polarity indication 

 

figure height 

13 mm (0.52") 

sampling rate 

2 - 3 readings / sec. 

guaranteed zero reading for 0V input 

 

high input impedance 

> 100 MOhm 

accuracy 

± 0.5% 

power consumption 

1 mA DC 

dimensions 

68 x 44 mm 

dissipation 

1 - 2 mA 

power requirement 

10 - 20 mW 

Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage 
or injury resulting from (incorrect) use of this device.  