![background image](http://html1.mh-extra.com/html/velleman/personal-scope-hps5/personal-scope-hps5_manual_4104867015.webp)
15
PersonalScope
TM
Screen memory
It may be useful to "freeze" certain signals on
your screen. This will allow the user to study the signal or
perform measurements with the markers.
Press ‘Hold’ to freeze the screen.
F
The screen is also saved when the unit is deacti-
vated.
F
The memory will be erased if “reset” is pressed or if
the battery voltage is too low.
Set-up function keys
The selected function is dis-
played in the bottom right
hand corner of the screen.
The four blue function keys
work in conjunction with the
arrow keys.
The markers
The user can perform measurements on a certain
signal by using the four moveable markers.
This can be useful
when measuring the
interval between two
points or the ampli-
tude of any given
peak.
The following indications will appear on the screen :
T
he time interval between two vertical
markers.
T
he calculated frequency (primarily used for
the measurement of periods).
T
he voltage between two horizontal mark-
ers.
The markers can be moved through the arrow keys.
Keeping the key pressed down will move the marker
quickly, pressing it briefly will move the marker by 1
position. The
“mark 1-2”
key is used to select the desired
marker.
Hold
mark 1-2
HPS5
mark 1-2
trig
t-V/div
Y-pos
probe
x1/x10
Hold
Display
AC/DC
Auto
Reset
Charge
Slope
Trigger
mode
P E R S O N A L
S C O P E
Trigger
mode
Slope
OPERATION