q

R1 : 270         (2-7-1-B) 

q

R2 : 18K         (1-8-3-B) 

q

R3 : 18K         (1-8-3-B) 

2. 1/4W Resistors

 

R...

 

 

 

 

 

 
 
 

 

 

 

 

 

q

1. Jumper wires 

Construction 

By using the jumpers, the receiver can be set up for two 
output possibilities: 

 

1.

The output is on 

while the transmitter is pressed 

(MOMENT), this is mostly used for operating a door lock, 
garage door etc. 

 

2.

The output switches  (on/off) 

every time the transmitter is 

pressed (toggle), this setting is mostly used for switching 
alarms in and out, for operating central door locking systems, 
for switching a lamp on and off, etc. This setting must be 
used for use with our car alarm K3504. 

NOTE :  

q

R4 : 33K         (3-3-3-B)  

q

R5 : 5K6         (5-6-2-B) 

q

R6 : 2K7         (2-7-2-B) 

q

R7 : 6K8         (6-8-2-B) 

q

R8 : 6M8        (6-8-5-B) 

q

R9 : 1K           (1-0-2-B) 

q

R10 : 1K         (1-0-2-B) 

q

R11 : 100K     (1-0-4-B)   

q

R12 : 47K       (4-7-3-B) 

q

R13 : 47K       (4-7-3-B) 

q

R14 : 470       (4-7-1-B) 

q

R15 : 470K     (4-7-4-B) 

q

R16 : 10K       (1-0-3-B) 

q

R17 : 10K       (1-0-3-B) 

q

R18 : 10K       (1-0-3-B) 

q

R19 : 220K     (2-2-4-B)  

q

R20 : 680       (6-8-1-B)  

q

R21: 2K2        (2-2-2-B) 

Содержание K6707

Страница 1: ...gle or momentary contact Separate output to switch car alarm on or off Power supply 2 x 9VAC or 12 to 16VDC 100mA max Dimensions 76 x 84mm 3 x 3 4 modifications reserved Easy to build no coils to be m...

Страница 2: ...2 VELLEMAN Components NV Legen Heirweg 33 9890 Gavere Belgium Europe www velleman be www velleman kit com...

Страница 3: ...nose pliers for bending leads or to hold components in place Small blade and Phillips screwdrivers A basic range is fine For some projects a basic multi meter is required or might be handy 1 2 Assemb...

Страница 4: ...e to the solder joint REMOVE THEM FROM THE TAPE ONE AT A TIME Velleman hereby certifies that the device K6707 meets the essential requirements and all other relevant stipulations of directive 1999 5 E...

Страница 5: ...e Orange Orange Orange Orange Orange Oranje 3 4 Giallo Amarelo Amarillo Keltainen Gul Gul Gul Gelb Yellow Jaune Geel 4 5 Verde Verde Verde Vihre Gr n Gr n Gr nn Gr n Green Vert Groen 5 6 Blu Azul Azul...

Страница 6: ...nsmitter is pressed toggle this setting is mostly used for switching alarms in and out for operating central door locking systems for switching a lamp on and off etc This setting must be used for use...

Страница 7: ...q IC3 14p q IC4 14p 7 IC sockets checkthepositionofthenotch IC 1 q C1 2pF 2p2 q C2 2pF 2p2 q C3 22pF q C4 82pF q C5 330pF 331 q C6 330pF 331 q C7 330pF 331 q C8 100nF 104 1 q C9 100nF 104 1 6 Capacit...

Страница 8: ...F199 q T2 BC547 q T3 BC547 10 Transistors T T T T T q C10 1 F q C11 1 F q C12 1 F q C13 1 F q C14 1 F q C15 470 F 8 Capacitors Watch the polarity C q VR1 7809 12 Voltage regulator q CV1 5pF 5p5 11 Cap...

Страница 9: ...IC1 UM3758 120A q IC2 RV4558 LM258 2904 q IC3 CD4013 q IC4 CD40106 15 ICs checkthepositionofthenotch IC PIN 1 1 q RY1 VR10V12 14 Relays RY Affix the supplied sticker to the housing 16 Sticker Velleman...

Страница 10: ...ting the code The code is set by connecting one or more code points to a neighboring or point using the small jumpers Code points may also be left unconnected open see figure a No connection b Code co...

Страница 11: ...or is just on the verge of lighting up If not the tuning capacitor will have to be adjusted a little Do not touch the circuit with your hand 2 Tuning one or more transmitters to the receiver Activate...

Страница 12: ...ransformer 3 Other connections When using the relay output there is a choice between a normally closed contact NC or a normally open contact NO The common output is at COM Connection 19 Connection A C...

Страница 13: ...hboard using the LED holder supplied When the relay is closed the LED will flash when open it is continuously lit NOTE The circuit can also be installed in a plastic housing For installation in the ca...

Страница 14: ...14 PCB layout PCB...

Страница 15: ...10 11 SET CLK R15 8 Q 13 10 D FF2 11 12 9 N1 RST Q 2 1 D1 C1 CV1 R2 C4 R5 R4 T1 C6 C3 L2 V R1 R8 C10 R9 V L1 R7 C7 R3 R10 V A1 1 3 2 6 4 5 V 8 C2 VB VA GND A8 C5 VSS 17 R17 C13 R16 T2 RY1 V1 D5 NO CO...

Страница 16: ...16 Modifications and typographical errors reserved Velleman Components nv H6707IP 2002 ED2...

Отзывы: