HAM982K_v2
VELLEMAN
6
SOUND
MEANING
1 short beep
successful key entry
2 short beeps
successful code entry for the function
5 short beeps
•
wrong code
•
unauthorized command attempted
•
code entry time expired, 10s max. per digit is allowed
1 long beep
exit delay expired, system is armed
1 short beep/30s
•
AC power failure
•
weak battery
continuous beep every 0.5s
•
exit delay time
•
entry delay time
•
DAP jumper is on
2 beeps + 5 beeps
system cannot be armed instantly due to
ARM PROHIBITED
b. Connections
BATTERY: connect the red (+) wire to the positive and the black (-) wire to the negative terminal of the battery. The
battery should be of the 12V / 1.2Ah sealed lead acid rechargeable type. It is protected by a 2.5A resettable
fuse and is charged by a current limiting regulated voltage source in the system.
1, 2 the device requires a 16.5Vac power supply, min. 1.5A at 50 or 60 Hz. The primary side of the transformer
must be connected to an unswitched receptacle.
3 This terminal provides an unsw12V output power referring to the common ground. It gives continuous
output power, even if the device is unarmed. Suitable for e.g. smoke detectors, control keypads etc. This
terminal is equipped with a 750mA resettable fuse.
4 This terminal provides a sw12V output power referring to the common ground when the system is
armed. It is provided for devices that require switched power for resetting, such as glass-break detectors and
smoke detectors that require a power-down to reset. This terminal is equipped with a 750mA resettable fuse.
3+4 These terminals share the same power bus. Combined power for these outputs should not exceed 750mA.
5 Common ground (-)
6 This terminal provides a cont12V output power at normal (= no alarm) condition that is switched off
when an alarm occurs. It is intended for alarm devices with a built-in battery that remain quiet as long as there
is an incoming voltage (hold-off voltage) and that are activated (on battery power) when the voltage is cut.
7 This terminal provides a cont12V output power upon and after an alarm condition until the system is
disarmed or reset by the user code. It is equipped with a 2.5A resettable fuse. This output is intended for alarm
devices that switch on when there is incoming power (e.g.:
SV/PSL3x
siren + strobe).