HAM982K_v2
VELLEMAN
5
d. Testing
a. Apply 12V DC power and allow 3-5 minutes for the detector to warm up and stabilise before testing.
b. Walk into the protected area at a speed of 1 step per second and watch the LED.
c. The alarm will be triggered when movement is detected. If the pulse count jumper is set to "harsh", 2 detections
need to be made in 12 seconds time for the alarm to be triggered.
d. If proper detection does not occur during the walk tests, relocating or re-aiming the detector may be required.
4. Magnetic Reed Switches
•
magnetic switch, standard type
•
white ABS
•
mounting with screws or double-sided tape
•
operating gap: max. 15mm
•
dimensions: 51 x 13 x 13mm.
5. Panic button
•
NC & NO alarm circuit connection
•
screw connectors
•
momentary contact (off / on)
•
contact rating: 0.5A / 24Vdc max
•
colour: ivory
•
dimensions: 76 x 22.5 x 16mm
6. Control Panel
a. Front Panel
LEDs
ON
OFF
FLASHING
zone LEDs (8) zone unsealed – wire is
possibly disconnected.
Zone sealed (normal)
•
fast: zone is/was in alarm
•
fast with interval: zone is in alarm memory –
system disarmed
•
slow: zone is isolated
exit/armed
alarm armed
alarm disarmed
exit delay period
•
AC power failure, system runs on battery
(flashing starts 20-30s after power failure)
AC power
system on AC power
•
'AC power' & 'battery' flashing alternatively:
system is in power-up delay period
battery
battery faulty
normal
•
battery is under test
program
system in program mode normal
arm prohibited
system in arm prohibited
mode: indicator is on
during exit delay period
•
System armed (exit delay
expired)
•
System forced to arm
system cannot be armed after exit delay
expired due to faulty zone(s) – see zone
indicators for the faulty zone(s)