HAA85WP
VELLEMAN
6
10.
Use the Keypad – Taking the Stored Data Above as Reference
1) To command the outputs 1, 2 & 3, enter the corresponding codes into the keypad and validate via #.
2) The Personal Master Code is also the
SUPER USER CODE
for output 1, 2 and 3. It allows the owner to use
ONLY ONE
code to operate the 3 outputs. To command outputs 1, 2 & 3, enter the Personal Master Code into
the keypad and validate via #
PLUS
and the corresponding output numbers.
3) The
DURESS CODE
does not need to be programmed. The keypad determines it automatically by increasing the
first digit of the User Code 1 by
TWO
units.
e.g. If we have the User Code 1 is 1234, then the keypad will determine the Duress Code as 3234.
In the above programming example, we have made User Code 1 as 8321, the Duress Code has been determined
as 0321 automatically by the keypad.
To command the
DURESS OUTPUT
, enter the Duress Code by increasing the first digit of Code 1 of
TWO
units
and validate via #.
The Duress Code has a double action. It controls the Relay Output 1 at the same time as the User Code 1 and
activates the Duress Output. The Duress Code can always activate and deactivate the Relay Output 1, but can
not deactivate the Duress Output.
ONLY
the composition of the User Code 1 can deactivate (reset) the Duress
Output.
4) To command the outputs using
ACCELERATED CODE
, if the one output from 1 to 3, has been programmed in
Start/Stop with the Accelerated Code, it is possible to activate with only the
FIRST TWO
digits, from Code 1 to
Code 3, of the corresponding code. Deactivating of this output always requires the composition of the Complete
Code.
In this example, the Output 3 has been programmed in Start/Stop Mode with Accelerated Code.
The Complete Code 3 : 9270 The Accelerated Code: 92
0 3 2 1
#
Duress output activates, and relay output 1 activates for 5
seconds.
8
3 2
#
2
9
8
3 2
#
1
9
Output 2 starts.
Output 1 activates for 5 seconds.
8
3 2
#
3
9
Output 3 starts.
9 2 7 0
#
Output 3 stops
9 2
#
Output 3 starts
8 3 2 1
#
Relay output 1 activates for 5 seconds
9 2 7 0
#
Output 3 starts (or stops)
6 8 5 4
#
Output 2 starts (or stops)