DVM2000
VELLEMAN
15
Diode
Range Resolution Accuracy
2.5V
0.1mV
± (1% + 5)
Test current
≈
0.7mA
Logic Frequency
Frequency Range
Sensitivity
Accuracy
5Hz~2MHz
Vp 2~5V square wave
± (0.006% + 4)
Linear Frequency
Frequency Range
Voltage/Current Range
Sensitivity
Accuracy
5Hz~200kHz
(sine wave)
500mV 100mV
± (0.006% + 4)
5V 0.5V
50V 4V
500V 40V
1000V 400V
5000µV 1mV
500mV 100mV
Accuracy lowers for low voltage or low frequency.
Duty Cycle
Frequency Range
Duty Cycle Range
Resolution
Accuracy
5Hz~500kHz
5%~95%
0.01%
± (2% + 5-
Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulted from
(incorrect) use of this device.
For more info concerning this product, please visit our website www.velleman.eu.
The information in this manual is subject to change without prior notice.