Example:
PWD:1234,SENDMS4:9,GoodMorning%
Password 1234
SMS message “Good Morning” will be sent to phone number 4.
Reply message:
Success!
:
CU2200
succeeds in sending message.
Default! NONB
: no preset phone number, operation failed.
Default!
: Operation failed but phone number exists.
•
Relay Output Control
Command: PWD:XXXX,COUTN:Y%
Password 1234
N
Relay output channel (1 ~ 3) (outputs 2 and 3 not available)
Y 1
0
Turn on (close) the output
Turn off (open) the output
The relay output is N.O. by default.
Command
COUTN:1
is not valid when the relay output is triggered by alarm. Reply message will be
ST:XXX
in
this case.
In the above case, command
COUTN:0
is used to reset the relay output after the alarm is triggered.
•
Relay Output Delay Time
Command: PWD:XXXX,OUTNDLAY:YYYY%
XXXX Password
N
Relay output channel (1 ~ 3) (outputs 2 and 3 not available)
YYYY
0000 – 9999 seconds
0000 Turn the output on or off (default)
0005 Turn on the output for 5 seconds and off again
Turn off the output for 5 seconds and on again
The relay output delay time is good for controlling e.g. an electric door lock.
•
Operating Voltage Low Level Alarm Message
When the power supply voltage level is below the minimum level at 5.34VDC, the
CU2200
will send an alarm
SMS message.
Date 2007-06-15
Time 13:25
ST:001;TM200706121325;V:5.34#
•
Operating Voltage Low Level Alarm
This command is used to set the action to be taken once the operating voltage drops below 7.0VDC. Value of
the current operating voltage can be retrieved by command 2.
Command: PWD:XXXX,ADCOUT0:YY,ZZZZ,NNN%
XXXX Password
YY
00 means alarm not reported to control centre
10 means alarm reported to control centre 1
01 means alarm reported to control centre 2
11 means alarm reported to control centre 1 and 2