Before installing the mini pan/tilt dome, it must be configured though setting the
dipswitches that are located inside the dome. To reach the dipswitches, open the dome by
rotating the transparent cover (
2
) clockwise and lifting it.
•
Be very careful not to touch any other part inside the housing while setting the switches,
as damage might occur.
•
SW1~SW4 are used to set the ID of the device, allowing for a system with up to 15
unique devices. However, when using the IR remote control device, only the 9 first
(lowest) IDs can be controlled.
•
SW5 and SW6 set the BAUD rate, SW7 the used protocol and SW8 sets the type of alarm
contact to normally open (N.O.) or normally closed (N.C.).
ID
SW 1
SW 2
SW 3
SW 4
0
OFF
OFF
OFF
OFF
SW 5 SW 6 BAUD rate
1
ON
OFF
OFF
OFF
ON
ON
2400
2
OFF
ON
OFF
OFF
OFF
ON
4800
3
ON
ON
OFF
OFF
ON
OFF
9600
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
SW 7
Protocol
7
ON
ON
ON
OFF
ON
Native
8
OFF
OFF
OFF
ON
OFF
PELCO
9
ON
OFF
OFF
ON
10
OFF
ON
OFF
ON
11
ON
ON
OFF
ON
SW 8
Alarm type
12
OFF
OFF
ON
ON
ON
N.O.
13
ON
OFF
ON
ON
OFF
N.C.
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
•
Close the dome by placing the transparent cover (
2
) back and turning it counter
clockwise. Secure the transparent cover by mounting a small screw in the hole in the
housing.
Dome
1. Camera
2. Transparent cover
3. Non-transparent housing
4. Mounting plate
5. Input/output cable
5a. video output (BNC)
5b. power input
5c. communication
IR receiver
6. DC power input
7. RS-485 D+
8. RS-485 D-
9. Ground
Содержание CAMCOLD7