12
Mount the transformer as in the drawing (see also the picture on the packaging)
Use the supplied straps (4 pcs) to fix the transformer.
Primary windings (MAINS) connection:
Check the table on the PCB for the correct voltage selection and connect
the wires :
For 230V (220V to 240V), edge orange, then brown and black.
For 115V (110V to 120V), edge brown, then orange and black.
Using a black marker, erase the not used voltage on the rear panel of the
unit!
Secondary windings connection:
Connect the Red, Yellow, Blue and Grey wire to the SK5/SK6 connector, check
the colors on the PCB.
24. Mounting the power transformer and mains voltage selection
Construction
230V
120V
ORANGE
BROWN
BROWN
ORANGE
BLACK BLACK
Содержание HIGH-Q K8040
Страница 2: ......
Страница 23: ...23 32 PCB PCB ...