ATTENTION

The lights on the device show whether it is working correctly. Check this 
regularly. If fewer lights are visible, the electric circuit is being disturbed 
by contact with an animal, vegetation, branches or snow, for example. 
Check the area around the electric fence to see whether it is in contact 
with something like the above.
If only one light is visible, there is a malfunction. Check the energizer by 
disconnecting the red and black wires from the unit. If the series of lights 
flash, the energizer is working correctly but there may be a problem with 
the fence. Make sure the circuit is intact, check all the connections and 
the earthing system. If only one light is visible, the energizer is broken.
If the power cord is damaged, it must be replaced by the manufacturer, in 
order to avoid a hazard.

SAFETY

Other than the shock response, the Ultra Protector is safe for humans and 
animals. Make sure that people in your area 

(especially children!)

 are aware 

of the electric fence and advise them to stay away from it. Shut down the 
system temporarily if there are activities or people working near the fence. 
Do not dispose of electrical appliances as unsorted municipal waste, use 
separate collection facilities. Contact you local government for informa-
tion regarding the collection systems available. If electrical appliances are 
disposed of in landfills or dumps, hazardous substances can leak into the 
groundwater and get into the food chain, damaging health and well-being.

GUARANTEE

Velda guarantees the correct functioning of this apparatus for a period of 24 
months after purchase. The warranty expires in case of repairs or changes to 
this product that are performed  by others than Velda. If a claim to guarantee 
can be laid, a dated receipt should be presented. Visit 

www.velda.com/

service

 for the warranty procedure and terms.

Velda cannot guarantee that device has been correctly installed and is operating 
correctly and we cannot be therefore be held liable for any damage that may 
occur.

STEP 2: 

installing electric wire

Use the hooks on the sides of the uprights to position the electric wire. 
Pass the wire through the lower hooks first, then tie a knot and pass the 
same wire through the upper hooks. After installing the wire, tie it up again 
at the end.

N.B.

 Do not cut the wire: make sure the lower and upper wire are con-

nected to each other! After the last connection has been made, the excess 
wire can be cut off. Make sure the wire cannot come into contact with 
objects and vegetation in any weather conditions.

STEP 3: 

connect the earth pin

The metal earth pin consists of 2 parts and a threaded connection. Connect 
the parts and tighten well. Decide where to locate the earth pin near the 
fence and watch out for roots and pipes in the ground. Push the earth pin 
into the ground until the eye is no more than 5 cm above the ground (use an 
auger if necessary). Empty at least one bucket of water around the earth pin.
Attach the eye end of the black earth wire (5 m) to the eye of the earth pin 
with the bolt and washers (see image A). 

STEP 4: 

electric fence unit

Select a location for the energizer within 4 metres from the fence. Put the 
rainproof device in a place where it is clearly visible from the house or 
terrace (screws and plugs included).
The blue clip with the metal plate connects the electric fence to the red 
pulse wire. Close the clip around the lower electric wire with the wire in 
the inlet. 

N.B.

 Once you close the clip, it cannot be released! Insert the 

blue clip in the light-blue connector of the red wire so that the two are 
connected (see image B). Attach the other end of the red wire to the 
red connector of the energizer. Place the metal eye under the red screw, 
position the washer and tighten firmly. Attach the black earth wire to 
the black connector of the energizer in the same way. The installation 
is now ready for use. Activate the energizer by connecting the cable to 
the power supply. One LED lights up when the unit is working and the 
series of lights show the intensity of the pulses.

Содержание Ultra Protector

Страница 1: ...Ultra Protector velda...

Страница 2: ...op staanders piquets St nder schrikdraad fil lectrique Abschrekdraht aardepin piquet de terre Erdungsstift aansluitdraden filsdeconnection Anschlussdr hte schrikdraadapparaat Energizer Netzger t A B B...

Страница 3: ...jn dan wat hieronder wordt aangegeven Minimale afstand tussen stroomleidingen en elektrische afrasteringen Spanning stroomleiding V Afstand m 1000 V 3 m 1000 en 33 000 V 4 m 33 000 V 8 m Indien aanslu...

Страница 4: ...alliert werden sollten folgende Mindestabst nde eingehalten werden Minimal Abst nde von Elektroz unen zu Hochspannungsleitungen Stromspannung V Abstand m 1000 V 3 m 1000 und 33 000 V 4 m 33 000 V 8 m...

Страница 5: ...indiqu s ci apr s D gagements minimaux sous les lignes a riennes de transport d lectricit Tension sur la ligne lectrique D gagement en m tres 1000 V 3 m 1000 et 33 000 V 4 m 33 000 V 8 m Si les fils...

Страница 6: ...ances shall not be less than those shown in the table below Minimum clearances from power lines for electric animal fences Power line voltage V Clearance m 1000 V 3 m 1000 and 33 000 V 4 m 33 000 V 8...

Страница 7: ...iveer het schrikdraadapparaat door de stekker aan te sluiten op een droog stopcontact Een controlelampje gaat branden wanneer het apparaat is ingeschakeld en de lampenreeks geeft de intensiteit van de...

Страница 8: ...overhandigd Ga naar www velda com service voor de garantieprocedure en voorwaarden Daar Velda geen invloed kan uitoefenen op de juiste installatie en werking van dit apparaatkunnenwijnietverantwoordel...

Страница 9: ...rwenden Sie die Einl sse an der Seite der St nder um den Draht zu spannen F hren Sie zuerst den Draht durch die unteren ffnungen verknotenihnundf hrendenselbenDrahtdannzudenoberen ffnungen Nach dem Sp...

Страница 10: ...oi pr sent Activer l lectrificateur en branchant la fiche dans une prise de courant s che Un voyant de contr le s allume quand l lectrificateur est sous tension et la barre de voyants indique l intens...

Страница 11: ...jeu de la garantie doit s accompagner de la pr sentation du bon d achat dat Visitez www velda com service pour la proc dure et les conditions tant donn que Velda n a aucune in fluence sur l installati...

Страница 12: ...ating correctly and we cannot be therefore be held liable for any damage that may occur STEP 2 installing electric wire Use the hooks on the sides of the uprights to position the electric wire Pass th...

Страница 13: ...or pond use The product and its accessories have been tested to comply with the following European directives 2014 30 EU Electromagnetic Compatibility Directive EMC The product compliance with the dir...

Отзывы: