Veit Brisay Fuse Master BX Series Скачать руководство пользователя страница 9

The fusing process 

 

The part to be fused is placed on the loading table. Please 
ensure, that the cut of the interlining is 2 mm smaller than the 
fabric as other wise the belts could get soiled. 
The fabric together with the interlining is put on the belt. Please 
note: if only one operator is working on the machine, the part to 
be fused should be placed on the belt on the right side of the 
machine which is marked °C, as the temperature sens ors are 
located in this area. 
The required fusing time can be set on the speed metre.  
 
When the article is in the machine, the upper heating zone 
warms up the material. The required temperature is set on the 
thermostat. The articles are transported between the seamless 
belts towards the main heating zone. Here the lower heating 
zone applies heat to the articles. The desired temperature can 
be set on the thermostat. 
Then the articles are transported to the pressure cylinder, where 
fabric and interlining get fused. The articles, still warm, leave the 
machine and reach the cooling belt, where the articles can be 
taken off manually or be stacked. 
 

 
 
 

 

Содержание Fuse Master BX Series

Страница 1: ...Handbook BX 1000 BX 600 Pressing for Excellence GB...

Страница 2: ...ystem with continuous upper and lower belts a cooling station with long life polyester belt a control unit for easy operation and reading Long life maintenance free elements and good insulation reduce...

Страница 3: ...ture and pressure and fusing time thanks to the clearly marked symbols The set and actual working temperatures are digitally indicated and easily read Control elements G1 adjustment of the fusing time...

Страница 4: ...ded 2 Clean the belts with the cleaning cloth 3 Turn the wiper bar with a clean surface facing the belt 4 Clean the delivery rail to the cooling belt and the stripping rail with a soft cloth 5 Drain t...

Страница 5: ...arp tools for cleaning This shortens the belt life Covers or towels of cleaning bars or cleaning devices should regularly be checked or replaced Transfer and strip off blades should be cleaned in regu...

Страница 6: ...cleaning agent KANFIX is not only suitable for cleaning the Teflon coated belts It also conserves the belts as an additional coating on the belts to avoid agglomeration of glue residues The cleaning...

Страница 7: ...lean between the belts The cleaning cloth should be used as often as possible i e during every break mornings lunchtime etc and at the end of the day Do not leave the cleaning cloth in the machine ove...

Страница 8: ...ANFIX KANfix contains no silicon Silicone containing cleaning agents cause damages to the belts the heating elements and the rubber coated rollers KANfix 250g container Art Nr 214 607 4 KANfix box wit...

Страница 9: ...ors are located in this area The required fusing time can be set on the speed metre When the article is in the machine the upper heating zone warms up the material The required temperature is set on t...

Страница 10: ...y The heating system of the Fuse Master BX The heating surface consists of a series of metal profiles that form a curved panel Heating circuits are laminated directly onto the inside of the contact su...

Страница 11: ...kind of material as well as the kind of interlining Therefore we recommend exactly following the fusing recommendations of the interlining manufacturers and always carrying out preliminary tests The...

Страница 12: ...cisely adjustable by means of pneumatic cylinders A sturdy pressure rocker provides for constant pressure over the entire working width The specific pressure is changed by adjusting the air pressure T...

Страница 13: ...kind of interlining or fabric Therefore the interlining manufacturers indicate the required bond strength per interlining Appearance of adhesion test After fusing fabric and interlining are pulled ap...

Страница 14: ...s We recommend covered paper measuring tapes in order to minimize the influence of humidity of the fabric These paper measuring tapes can be ordered from Kannegiesser Garment Textile Technologies GmbH...

Страница 15: ...ness Furthermore the pressure roller should be checked for faults and contractions which can be caused by aggressive cleaning agents Fusing without problems One of the specific characteristics of garm...

Страница 16: ...ff fe ec ct t M Mo oi ir re ee e E Ef ff fe ec ct t P Pl le ea at ts s M Mo ov ve e o of f I In nt te er rl li in ni in ng g R Re es si in n S So oi il li in ng g P Pr re es ss su ur re e t to oo o h...

Страница 17: ...and actual working temperatures are digitally indicated and easily read Disturbance diagnostics All electrical and mechanical machine functions are permanently controlled by an automatic diagnosis sys...

Страница 18: ...instructions for information regarding spare parts and further technical details Kannegiesser Garment Textile Technologies GmbH Valdorfer Stra e 100 Postfach 1612 D 32602 Vlotho Germany Telefon phone...

Отзывы: