Factory Default: Pelco-D or Pelco-P (Auto detection)
Veilux Model # VP-58CND12X User Manual
DIP SWITCH SETTING
C. PROTOCOL SETTING
7
th
~8
th
dip switches are used for Protocol Setting.
D. BAUD RATE SETTING
The 9
th
Dip Switch is used for BAUD RATE setting.
DIP SW can be changeable to 2400bps, 9600bps.
Factory Default: 2400bps. (If user selects Vicon protocol, then Baud rate is automatically set
as 4800bps.
E. 485 TERMINATIONS
10
th
Dip Switch is used for 100Ω termination.
Set on 10
th
Dip Switch only for the last looped camera from the controller.
Even in case of only one camera, set on 10
th
Dip Switch of the camera.