38
AC310 Universal AC Drive Service Manual
3.4.2 Analogue Output Signal
(
AO1
,
AO2
)
:
Voltage 0-10V; Current
4-20mA ,0-20mA
;
Frequency Signal 0-50KHZ
⚫
Test the output voltage: DIP switch to A01 or AO2 voltage ON terminal, at this time
parameter setting F03.37=0, F03.38=1, check C00.20 or C00.21, then press the start button,
there will be voltage from 0-10V (after parameter setting or use multimeter DC gear, measure
+10V).
F03.38=1, check C00.20 or C00.21, then press the start button, there will be a voltage
from 0-10V (after the parameters are set up or use a multimeter DC gear, measure the voltage
b10V and GND, the operation will be from 0V to 10V). Figure 3 (Run to maximum
Содержание AC310
Страница 23: ...22 AC310 Universal AC Drive Service Manual 2 7 Switching Power Supply...
Страница 47: ...46 AC310 Universal AC Drive Service Manual 3 7 Keyboard Circuitry...
Страница 54: ...53 AC310 Universal AC Drive Service Manual 3 10 Current Acquisition Detection and Maintenance...
Страница 55: ...54 AC310 Universal AC Drive Service Manual 3 11 OC Fault Detection and Maintenance...