AC310 Universal AC Drive Service Manual
17
1. Use the DC adjustable voltage regulator to connect to the P-N terminal of the machine
under test, and hang the multimeter pen on the P-N, and set the multimeter to DC voltage
(DC); note that the software voltage correction factor is 100% before testing. Compare the
value displayed by multimeter and keyboard
2. Measure the voltage at this point of the VPN: (get the VPN voltage from the voltage
scaling relationship)
S2 model
T3
model
579V homologous 5V
1000V homologous 5V
4. Vulnerable components op amps
5. Device bit number and specification
Resistive
R82/R83/R84/R85/R2/R3=470K/1206
R4/R5/R95/R96/R97/R98=470K/1206
Double diode
D70/D71=BAV99LT1G
Op amp
U75=LF353DRG4
R79/R99=10K/0805
R80/R100=4.02K/0805
C82/C87=10Nf/0805
C86/C81=100NF/0805