Important information
The regulations set by the truck manufacturer must always be
followed.
One 3A fuse must always be mounted as close to the supply
connector as possible. See page 4, 9 or 10.
All cables must be mounted so that they
can’t
be pinched. The
cable isolation must not be damaged.
All cables coming out of the Connect5 box must be zip-tied to
something nearby (max 20cm), this to minimize oscillation in
the connector.
All extension cables must be cut to length, do NOT wind up
excessive cables in spools.
It is important that the Connect5 box is well fixed to avoid
vibrations!
High reliability and trouble-free performance of the system is
achieved only by high quality installation. Do not make any
cable by-pass connections.