background image

3

VEGAVIB 61, 62, 63

53863-EN-170828

Area of applicability

These safety instructions apply to the vibrating level switches VEGAVIB VB6*.C****Z**** with 

integrated electronics module VB60Z according to Certificate of Conformity IECEx PTB 07.0015 X, 

Issue 1 (certificate number on the type label) and for all instruments with the number of the safety 

instruction (53863) on the type label.

General information

The VEGAVIB VB6*.C****Z**** are used for level measurement in hazardous areas.
The measured products can also be combustible liquids, gases, mist or vapour.
The VEGAVIB VB6*.C****Z**** are suitable for use in hazardous atmospheres of all combustible 

materials of explosion group IIA, IIB and IIC for applications requiring instruments of EPL Ga, 

EPL Ga/Gb or EPL Gb.
If the VEGAVIB VB6*.C****Z**** are installed and operated in hazardous areas, the general Ex 

installation regulations IEC 60079-14 as well as these safety instructions must be observed.
The operating instructions as well as the installation regulations or standards that apply for explo

-

sion protection of electrical systems must generally be observed.
The installation of explosion-endangered systems must always be carried out by qualified person

-

nel.

EPL Ga instrument

The VEGAVIB VB6*.C****Z**** are installed in hazardous areas requiring a EPL Ga instrument.

EPL Ga/Gb instrument

The electronics housing is installed in hazardous areas requiring instruments of type EPL Gb. The 

process connection element is installed in the separating wall, which separates areas requiring 

instruments of type EPL Gb or EPL Ga. The antenna system with the mechanical fixing element is 

installed in hazardous areas requiring instruments of type EPL Ga.

EPL Gb instrument

The VEGAVIB VB6*.C****Z**** are installed in hazardous areas requiring a EPL Gb instrument.

Ignition protection label

Ex ia IIC T6 Ga, Ga/Gb, Gb

Important specification in the type code
VEGAVIB VB61/63(*).abcdefghij

Position

Feature

Description

ab - Approval

CI

Ex ia IIC T6 … T1 Ga, Ga/Gb, Gb

c - Version / Process tem

-

perature

A

Standard / -50 … +150 °C

B

with adapter / -50 … +250 °C

C

Detection of solids in water / -50 … +150 °C

E

with Carbocer coating, less buildup, no corrosion/abrasion protection / 

-50 … +150 °C

F

with Carbocer coating, less buildup, no corrosion/abrasion protection / 

-50 … +250 °C

G

Detection of solids in water with Carbocer coating, less buildup, no cor

-

rosion/abrasion protection / -50 … +150 °C

Содержание VEGAVIB 62

Страница 1: ...Safety instructions VEGAVIB 61 62 63 Intrinsic safety IECEx PTB 07 0015 X Two wire Document ID 53863...

Страница 2: ...ic electricity 7 6 Use of an overvoltage arrester 7 7 Impact and friction sparks 7 8 Potential equalisation 7 9 Installation 7 10 Material resistance 8 11 Locking mechanism of housing cover 8 12 Cable...

Страница 3: ...ally be observed The installation of explosion endangered systems must always be carried out by qualified person nel EPL Ga instrument The VEGAVIB VB6 C Z are installed in hazardous areas requiring a...

Страница 4: ...20 80 C E Cable FEP detection of solids in water 40 100 C K Cable PUR with Carbocer coating less buildup no corrosion abrasion protection 20 80 C L Cable FEP with Carbocer coating less buildup no cor...

Страница 5: ...Gb the intrinsically safe power supply and signal circuit must correspond to protection class ia For applications requiring instruments of type EPL Ga resp EPL Ga Gb the VEGAVIB VB6 C Z is preferably...

Страница 6: ...sor of VEGAVIB 61 63 65 and 67 is operated in hazardous atmospheres of zone 0 there is no danger of ignition if it is operated under non atmoshperic pressures from 1 to 16 bar and temperatures accordi...

Страница 7: ...ring operation maintenance and cleaning process related electrostatic charges e g by measuring media flowing past are ruled out 6 Use of an overvoltage arrester If necessary the VEGAVIB VB6 C Z can be...

Страница 8: ...stainless steel housing the lid has to be screwed into the stop and secured by screwing out one of the lid locking screws before setup of the instrument 12 Cable entries The supplied cable entry is s...

Страница 9: ...9 Notes VEGAVIB 61 62 63 53863 EN 170828...

Страница 10: ...10 Notes VEGAVIB 61 62 63 53863 EN 170828...

Страница 11: ...11 Notes VEGAVIB 61 62 63 53863 EN 170828...

Страница 12: ...of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change without prior n...

Отзывы: