1 About this document

VEGATOR 636 Ex • Signal conditioning instrument

23446-EN-130627

1  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for mounting, connection and setup as well as important instruc

-

tions for maintenance and fault rectification. Please read this informa-

tion before putting the instrument into operation and keep this manual 

accessible in the immediate vicinity of the device.

1.2  Target group

This operating instructions manual is directed to trained specialist 

personnel. The contents of this manual should be made available to 

these personnel and put into practice by them.

1.3  Symbolism used

Information, tip, note

This symbol indicates helpful additional information.

Caution:

 If this warning is ignored, faults or malfunctions can result.

Warning:

 If this warning is ignored, injury to persons and/or serious 

damage to the instrument can result.

Danger:

 If this warning is ignored, serious injury to persons and/or 

destruction of the instrument can result.

Ex applications

This symbol indicates special instructions for Ex applications.

• 

List

The dot set in front indicates a list with no implied sequence.

→ 

Action

This arrow indicates a single action.

1  Sequence of actions

Numbers set in front indicate successive steps in a procedure.

Battery disposal

This symbol indicates special information about the disposal of bat

-

teries and accumulators.

Содержание VEGATOR 636 Ex

Страница 1: ...Operating Instructions VEGATOR 636 Ex Signal conditioning instrument Ship approvals Document ID 23446...

Страница 2: ...duct description 3 1 Configuration 7 3 2 Principle of operation 8 3 3 Adjustment 8 3 4 Packaging transport and storage 8 4 Mounting 4 1 General instructions 10 4 2 Mounting instructions 10 5 Connectin...

Страница 3: ...ioning instrument 23446 EN 130627 Supplementary documentation Information Supplementary documents appropriate to the ordered version come with the delivery You can find them listed in chapter Product...

Страница 4: ...hese personnel and put into practice by them 1 3 Symbolism used Information tip note This symbol indicates helpful additional information Caution If this warning is ignored faults or malfunctions can...

Страница 5: ...explicitly forbidden 2 3 Warning about incorrect use Inappropriate or incorrect use of the instrument can give rise to application specific hazards e g vessel overfill or damage to system components t...

Страница 6: ...the Ex approved instruments 2 7 Environmental instructions Protection of the environment is one of our most important duties That is why we have introduced an environment management system with the g...

Страница 7: ...if necessary further certificates The VEGATOR 636 Ex consists of VEGATOR 636 Ex signal conditioning instrument 5 6 7 8 9 10 12 13 14 TEST on 3 1 2 Fig 1 VEGATOR 636 Ex 1 Ex separating chamber with Ex...

Страница 8: ...protected by packaging during transport Its capacity to handle normal loads during transport is assured by a test based on ISO 4180 The packaging of standard instruments consists of environment frien...

Страница 9: ...iption VEGATOR 636 Ex Signal conditioning instrument 23446 EN 130627 Storage and transport temperature see chapter Supplement Technical data Ambient conditions Relative humidity 20 85 Storage and tran...

Страница 10: ...cover IP 65 for surface mounting In this housing you can mount a maximum of 3 instruments of 36 mm width 4 2 Mounting instructions The plug in socket is constructed for carrier rail mounting according...

Страница 11: ...erminals according to the following illustration 1 2 4 3 Fig 3 Mounting the separating chamber All signal conditioning instruments are provided with different gaps dependent on type and version mechan...

Страница 12: ...Typ 600 1 5 6 7 8 14 13 12 10 9 4 3 2 1 EEx ia L1 N DISBUS 0 10V 9 8 7 3 2 1 C B A 12 Plug in socket 2 1 3 4 Fig 4 Plug in socket VEGATOR 636 Ex 1 Bridges for looping the operating voltage 2 Type cod...

Страница 13: ...round terminal The ground terminal on the outside of the sensor housing must be connected to the potential equalisation low impedance If potential equalisation currents are expected the connection on...

Страница 14: ...rsions make sure the Ex separating chamber is plugged above the sensor terminals The pins for type and Ex coding must also be inserted correctly 5 3 Wiring plan 3 5 4 1 2 5 6 7 8 1 2 3 4 9 10 12 13 14...

Страница 15: ...T EEx ia L1 N DISBUS 0 10V 9 8 7 3 2 1 C B A 12 Plug in socket 6 5 10 7 7 8 9 1 2 3 4 Fig 6 Display and adjustment elements 1 Test key 2 Control lamp level relay LED yellow 3 Control lamp Fault signal...

Страница 16: ...54W max 250VAC DC 9 10 Uo xx V Lo xx mH Co xx nF Po xx mW Io xx mA 1 2 3 Fig 7 Display and adjustment elements 1 DIL switch block 2 Type plate 3 Transparent cover 6 2 Adjustment elements Control lamps...

Страница 17: ...on delays independent of each other The delay refers to the switching function of the relay In the example see previous illustration mode A max detection of overfill protection is selected switch 1 T...

Страница 18: ...pushing the key the system is checked on the following criteria Switching function of the switching outputs Potential separation of the outputs The signal processing of the signal conditioning instru...

Страница 19: ...tching conditions occur in the correct sequence and the specified duration 20 then the test is passed and the instrument functions correctly Test not passed The specified times deviate considerably fr...

Страница 20: ...tioning instrument Level Signal current Sensor Sig nal lamp Switch ing output yellow Con trol lamp Failure red Outputs Mode B Dry run protection approx 16 mA Relay ener gized transistor conducts Mode...

Страница 21: ...49 1805 858550 The hotline is available to you 7 days a week round the clock Since we offer this service world wide the support is only available in the English language The service is free of charge...

Страница 22: ...ld the failure lamp extinguish the sensor will be defective Exchange the sensor or send it in for repair The red failure control lamp LED of the signal conditioning instrument lights Current value 23...

Страница 23: ...Internet homepage www vega com under Downloads Forms and certificates Repair form By doing this you help us carry out the repair quickly and without hav ing to call back for needed information Print a...

Страница 24: ...ly separable WEEE directive 2002 96 EG This instrument is not subject to the WEEE directive 2002 96 EG and the respective national laws Pass the instrument directly on to a spe cialised recycling comp...

Страница 25: ...t circuit proof Sensor operating voltage 15 18 V DC Detection line break 2 3 mA Detection shortcircuit 23 2 mA Configuration connection cable 2 wire Resistance per conductor max 35 Relay output Number...

Страница 26: ...n class II Electrical separating measures reliable separation VDE 0106 part 1 between power supply sensor input level relay and transistor output Functional safety SIL The instrument can be used in sa...

Страница 27: ...trument 23446 EN 130627 9 2 Dimensions 118 5 mm 4 67 134 mm 5 28 36 mm 1 42 54 5 mm 2 15 5 6 7 8 9 10 12 13 14 1 2 on 3 Fig 23 Dimensions VEGATOR 636 Ex 1 Transparent cover 2 Carrier rail 35 x 7 5 or...

Страница 28: ...of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change without prior n...

Отзывы: